Filling Loop: How to Find and Use Your Boiler Filling Loop

Quick answer

A filling loop is the connection that lets you add mains water to a sealed heating system to raise the boiler pressure. It is usually under the boiler, either as a silver braided hose with one or two valves, a lever-operated keyless link built into the boiler, or a socket that takes a filling key. After every use the valves must be closed and a hose type disconnected, as UK water regulations and manufacturer manuals require.

On this page
  1. What is a filling loop?
  2. Types of boiler filling loop
  3. Where is the filling loop on my boiler?
  4. Using each type of filling loop
  5. Should the filling loop be left open?
  6. What is a keyless filling link?
  7. Common filling loop problems
  8. Can I replace a filling loop myself?
  9. What to do next

What is a filling loop?

A filling loop is a short link between the cold mains water supply and the sealed heating circuit of a combi or system boiler. Opening it lets mains water flow into the heating system, which raises the pressure on the boiler gauge. Closing it cuts the link again.

That link is kept closed because heating water is not clean. It has been round radiators and pipes, often with inhibitor chemicals in it, so it must never be able to flow back into the drinking water supply. Under the Water Supply (Water Fittings) Regulations 1999, published on GOV.UK's legislation site, a sealed heating circuit is treated as a fluid category 3 risk, so the filling point needs backflow protection, typically a double check valve, and a flexible filling hose should be disconnected when it is not in use. The Worcester Greenstar 4000 installation manual puts it plainly: the filling loop should never be a permanent connection to the mains water supply.

Regular (heat only) boilers on an open vented system do not have a filling loop. They are topped up automatically from a small feed tank in the loft.

Types of boiler filling loop

There are three main types of boiler filling loop, and which one you have decides how you use it.

TypeWhat it looks likeHow it worksExamples in manufacturer guidance
External braided loopA silver braided hose between two pipes under the boiler, with one or two valves or tapsOpen the valves slowly, then close them and disconnect one end of the hoseGlow-worm, Worcester Bosch and many system boilers
Internal keyless filling linkA lever, often coloured, under the boilerMove the lever to let water in, then return it to closedWorcester keyless filling link (blue lever), Baxi Easyfill (green)
Filling keyA small port or socket under the front of the boiler, with a separate plastic keyInsert and turn the key to open, then close it and remove the keyWorcester internal keyed filling (black port at the front right)

Some boilers use a variation of these. The Ideal Logic Combi user guide, for example, describes a filling loop with blue handles that is connected for use, then disconnected, with a cap and plug refitted afterwards.

Where is the filling loop on my boiler?

The filling loop is usually directly underneath the boiler, among the pipes and valves that come out of the bottom. Look for a silver braided hose, a coloured lever or a small black or grey socket. Glow-worm describes internal loops as sitting underneath the boiler with taps on each side.

If there is nothing under the boiler, check these places:

  • The airing cupboard. On a system boiler with a hot water cylinder, the loop is often near the cylinder or the pipework feeding it.
  • Behind a boiler cover or pipe shroud. Some installations hide the pipes behind a removable plastic cover at the bottom. This is not the boiler case and is fine to take off.
  • In a drawer or with the paperwork. A loose braided hose or filling key is often stored away after installation.

For brand-specific locations, see our guides to Worcester boiler pressure, Vaillant boiler pressure and Baxi boiler pressure.

Take a photo of the pipes under your boiler while nothing is wrong. If you ever need to top up in a hurry, you will know which valve is which.

Using each type of filling loop

Whichever type you have, the principle is the same: with the system cold, open the loop slowly, watch the gauge rise to the normal range, then close it fully. Our guide to boiler pressure that is too low gives the full repressurising steps, and our guide to normal boiler pressure explains what the gauge should read.

  • Braided hose: if the hose is detached, connect both ends hand tight first. Open one valve fully, then open the other slowly. Close both when the gauge reaches the target, then disconnect one end and refit any caps.
  • Keyless link: move the lever slowly and watch the gauge closely, because keyless links can fill quickly. Return the lever fully to its closed position.
  • Filling key: insert the key, turn it as your user manual describes, then turn it back and remove it.

Only use the filling controls outside the boiler case. Never remove the boiler casing to reach a valve or link; anything inside the case is a job for a Gas Safe registered engineer. Fill slowly, because overfilling can push the pressure up to the relief valve setting.

Should the filling loop be left open?

No. The filling loop should always be closed after use, and a braided hose should be disconnected at one end. There are two reasons.

  • Water regulations. The 1999 regulations and manufacturer manuals treat the loop as a temporary connection, to protect drinking water from heating water.
  • Pressure creep. An open or partly open valve keeps feeding mains water into the system. The pressure rises until the relief valve opens and discharges through the pipe outside. If that pipe is dripping, check the loop first, then read our guide to the boiler pressure relief valve.

To check a loop is closed, look at the valve handles. On most quarter-turn valves, the handle or screwdriver slot sits across the pipe when closed and in line with the pipe when open. Then note the gauge reading with the system cold and check it again the next morning. If it has risen with the heating off, water is still getting in and the valve needs attention.

A keyless filling link is a filling loop built into the underside of the boiler, operated by a lever instead of a hose or key. Worcester Bosch says its keyless filling link comes as standard on its CDi Classic combi boilers and is available as an accessory for others, and that it is WRAS approved. Baxi's newer boilers use a green Easyfill link underneath. The advantage is that nothing goes missing and there is no hose to connect. The drawback is that the lever makes it very easy to leave the link slightly open, so always check it has returned fully to closed.

Common filling loop problems

ProblemLikely causeWhat to do
No hose or key anywhereRemoved after installation and lostBuy the correct loop or key for your boiler model from a merchant, or ask an engineer
Drip at the hose connectionWorn or missing rubber washerReplace the washer and tighten hand tight
Valve will not turnValve stiff from lack of useDo not force it. Ask a plumber or heating engineer
Pressure creeps up with the loop closedValve passing waterDisconnect the hose and call an engineer

Can I replace a filling loop myself?

An external braided loop sits outside the boiler case on the mains and heating pipework, so a competent DIYer can swap a like-for-like WRAS-approved loop kit with its backflow protection. It still means isolating the mains supply and the heating circuit, and a poor joint can flood a cupboard, so most people use a plumber. An internal keyless link is part of the boiler itself and should be replaced by a Gas Safe registered engineer.

What to do next

If you have found your loop and the pressure holds after topping up, you are done. If you are topping up every few weeks, the loop is only treating the symptom. Our guide to a boiler losing pressure shows where the water is likely to be going.

Frequently asked questions

What if my boiler has no filling loop?

Look under the boiler, in the airing cupboard and behind any pipe cover first, as the loop or key may be stored away. If there really is none, buy the loop or key specified for your boiler model from a plumbing merchant, or ask a heating engineer to fit a compliant filling loop with backflow protection.

Why is my filling loop dripping?

A drip at the end of a braided hose usually means the rubber washer inside the nut is worn, missing or not seated. Replace the washer and tighten the nut by hand. A drip from the valve body itself, or a valve that lets water through when closed, needs a plumber or heating engineer.

Can a filling loop make my boiler pressure too high?

Yes. If the loop is left open, or a worn valve lets water through when closed, mains water keeps entering the heating system. The pressure climbs until the relief valve opens near 3 bar. Close the loop fully, disconnect the hose and watch whether the pressure still rises.

Can I use any filling loop on my boiler?

Not always. A standard braided loop fits most external setups, but keyless links and filling keys are specific to the boiler maker and often the model. Check the part number in your user or installation manual, and make sure any loop you buy is WRAS approved with suitable backflow protection.

Fault code meanings can differ between boiler models and software versions. Always check the user manual for your exact model. This page is general information, not a substitute for an inspection by a Gas Safe registered engineer. Read our disclaimer.