Boiler Clicking but Not Lighting: Causes and Safe Checks

Quick answer

A boiler that clicks but will not light is trying to ignite: the clicking is the spark, and if no flame is detected after a few attempts the boiler locks out. The usual causes are a gas supply problem, a frozen condensate pipe or a worn ignition electrode. Check other gas appliances, your meter and the gas valve under the boiler, then reset no more than 2 or 3 times before calling a Gas Safe registered engineer.

On this page
  1. Why a boiler clicks when it tries to light
  2. Common causes
  3. Safe checks you can do yourself
  4. Ignition failure codes by brand
  5. When to call a Gas Safe engineer
  6. Typical repair costs in the UK

Why a boiler clicks when it tries to light

When your boiler gets a call for heat or hot water, it runs a start-up sequence. The fan starts to clear the combustion chamber, the gas valve opens and an ignition electrode sparks rapidly next to the burner. That spark is the fast clicking you hear. A flame sensing electrode (the same electrode on some models) then checks for a flame. If it does not detect one within a few seconds, the boiler shuts the gas off, tries again and, after a set number of attempts, locks out with a fault code.

So clicking without lighting means the spark is working but a flame is not being established or detected. Either the burner is not getting gas, the flame cannot burn properly, or the boiler cannot sense it.

A slower single click now and then is different. Relays on the circuit board click as they switch, and many boilers click once or twice as the diverter valve or pump starts. Occasional single clicks while the boiler is working normally are nothing to worry about.

Common causes

CauseSignsWho fixes it
No gas reaching the property (meter, prepayment credit, supply fault)The gas hob will not light eitherYou check, then your supplier or the gas emergency service
Gas isolation valve under the boiler closedRecent service or work on the boiler or meterYou check
Frozen or blocked condensate pipeFreezing weather, gurgling before the lockoutYou thaw it, engineer if blocked inside
Worn, dirty or misaligned electrodeClicks for several seconds, lights only sometimesGas Safe engineer
Gas valve faultSpark is fine but no gas reaches the burnerGas Safe engineer
Fan, air pressure switch or flue problemFan codes, unusual fan noiseGas Safe engineer
Circuit board (PCB) faultErratic behaviour, repeated lockoutsGas Safe engineer

Safe checks you can do yourself

  1. Check other gas appliances. Try the gas hob if you have one. If that will not light either, the problem is the gas supply, not the boiler.
  2. Check the gas meter. On a prepayment meter, check you have credit and that emergency credit has not run out. On a smart meter, look for supply messages on the in-home display. Make sure the lever on the meter is in line with the pipe, which means open.
  3. Check the gas isolation valve under the boiler. The valve on the gas pipe below the boiler, often with a yellow handle, should have its handle in line with the pipe. If the handle is across the pipe, it is closed. This sometimes happens after a service or other work.
  4. Check the condensate pipe in freezing weather. If it runs outside and it has been below zero, thaw it with warm (not boiling) water or a hot water bottle. Our frozen condensate pipe guide shows how.
  5. Check the thermostat and timer. Make sure they are calling for heat, so the boiler is actually being asked to fire.
  6. Reset the boiler as described in the manual. If it still fails to light after 2 or 3 attempts, stop and call an engineer.

If you smell gas at any point, do not press reset or operate electrical switches. Turn off the gas at the meter if you can do so safely, open doors and windows, leave the property and call the National Gas Emergency Service on 0800 111 999 (0800 002 001 in Northern Ireland). See our guide on what to do if you smell gas near your boiler.

Do not keep resetting beyond this. Repeated resets can hide a fault that needs repairing, and some boilers block further resets after too many attempts in a short time.

Ignition failure codes by brand

Most boilers show a specific code when they lock out after failing to light. The code does not tell you which part has failed, but it confirms the boiler tried to ignite, found no flame and gave up.

BrandIgnition failure codeNotes
VaillantF28Failed to light on start-up (F29 is flame lost while running)
Worcester BoschEA 227No flame detected
IdealL2Ignition lockout after failed attempts
BaxiE133Ignition failure or gas supply interrupted
Glow-wormF28Ignition failure when starting up
PottertonE133Interruption of gas supply or flame failure
VokeraA01Ignition failure, flame not sensed
ViessmannF4No flame signal

Code meanings can vary between model ranges, so check the manual for your exact boiler. Write down the exact code before you reset, because it disappears once the boiler restarts and it helps the engineer bring the right parts. If the boiler clicks, fails and shows a different code each time, mention that too, as it can point to a control board fault rather than a gas or ignition problem.

When to call a Gas Safe engineer

If the gas supply is fine, the isolation valve is open and the condensate pipe is clear, the fault is almost certainly inside the boiler. Call a Gas Safe registered engineer if:

  • the boiler still clicks and fails to light after 2 or 3 resets
  • it lights sometimes but not others, which often points to a worn electrode
  • it lights with a bang or a loud whoosh
  • the clicking carries on continuously without the boiler locking out
  • you see scorch marks, soot or melted parts around the boiler

The engineer will usually check the gas pressure at the boiler, inspect and clean or replace the electrodes, test the gas valve and fan, check the condensate trap and read the fault history on the control board. Never take the casing off to look at the electrode yourself. It sits in the sealed combustion chamber, and the gas valve and wiring around it must only be worked on by a registered engineer.

Typical repair costs in the UK

RepairTypical UK cost
Engineer call-out and diagnosisTypically £60 to £120
Ignition or flame sensing electrode replacedTypically £100 to £250
Ignition lead or spark generator replacedTypically £100 to £250
Condensate trap cleared or pipe reroutedTypically £80 to £250
Fan replacedTypically £200 to £400
Gas valve replacedTypically £180 to £400
Main circuit board (PCB) replacedTypically £250 to £600

Electrode jobs sit at the lower end because the part is inexpensive and quick to fit on most boilers. Prices rise with London labour rates, evening and weekend call-outs, brand-specific parts (a board for a premium or discontinued model costs more than one for a common Baxi or Ideal combi) and boilers that are hard to reach. If your boiler is under warranty, contact the manufacturer before booking an independent engineer.

For how many times it is safe to reset a boiler before you call an engineer, see our guide on how to reset a boiler.

Frequently asked questions

Why does my boiler click but not ignite?

The clicking is the ignition spark. If no flame is detected, the usual causes are no gas reaching the boiler, a frozen condensate pipe or a worn electrode. Check your gas supply and condensate pipe, then call an engineer if it still will not light.

Can I clean the ignition electrode myself?

No. The electrode is inside the sealed combustion chamber next to the burner and gas valve. Only a Gas Safe registered engineer should remove the casing and work on it.

Why is my boiler clicking when the heating is off?

Occasional single clicks are usually relays or valves switching, for example during a frost protection or pump exercise cycle, and are normal. Continuous rapid clicking with no flame is an ignition fault.

My gas hob works but the boiler will not light. What next?

If the hob lights, gas is reaching the property. Check the gas isolation valve under the boiler is open and the condensate pipe is not frozen, then call a Gas Safe registered engineer if it still fails.

Fault code meanings can differ between boiler models and software versions. Always check the user manual for your exact model. This page is general information, not a substitute for an inspection by a Gas Safe registered engineer. Read our disclaimer.