How to Reset a Glow-worm Boiler: Energy7 and Betacom 4 Steps

Quick answer

Check the gas, power, pressure and condensate pipe first, then press the reset button once for about one second on a Glow-worm Energy7, or the on/off button on a Betacom 4. Glow-worm's operating instructions say that if the fault has not cleared after three reset attempts, you should stop and contact a competent person, which for a gas boiler means a Gas Safe registered engineer.

On this page
  1. Which Glow-worm boiler do you have?
  2. Checks to make before you press reset
  3. How to reset a Glow-worm Energy7
  4. How to reset a Glow-worm Betacom 4
  5. Codes a reset can and cannot fix
  6. How to turn the heating on after a reset
  7. After the reset: limits, engineers and prevention

Resetting a current Glow-worm combi takes one short press of one button, but only after you have dealt with whatever made it lock out. Glow-worm allows three attempts for an ignition fault; after that it is a job for a Gas Safe registered engineer. For other brands, see our guide on how to reset a boiler safely.

Which Glow-worm boiler do you have?

The reset method differs between ranges, so find the model name first. It is normally printed on the front of the boiler and on the user instructions.

  • Energy7 combi (25c-A, 30c-A, 35c-A): Glow-worm's Energy7 operating instructions, document 0020300878_00 (March 2020). It has a dedicated reset key, which the manual calls the fault clearance key.
  • Betacom 4 combi (24c-A, 30c-A): the Betacom 4 operating instructions, document 0020238423_02 (August 2019). Reset is on the on/off button.
  • Ultracom, Easicom, Flexicom, Micron and older models: earlier control panels with different buttons, lights and code lists. We have not checked their manuals for this page, so follow the user instructions for your exact boiler, which Glow-worm publishes on its website.

Our Glow-worm fault code hub lists the codes we cover for each range.

Checks to make before you press reset

A reset only tells the boiler to try again. If the cause is still there, it locks out again and you have used up an attempt for nothing.

CheckWhat to look forWhat to do
Gas supplyDoes the hob or gas fire light? Is there credit on a prepayment meter?Top up. If nothing on gas works and you have credit, call your supplier.
Gas isolation valveThe handle on the gas pipe under the boilerIt should sit in line with the pipe; turn it back if it is across.
PowerIs the display lit? Has the fused spur or a circuit breaker tripped?Switch the spur back on or reset the breaker.
System pressureThe pressure gauge or reading on the displayBetacom 4: 1.0 to 1.5 bar. Energy7: within 0.5 to 2.7 bar. Top up with the filling loop if low.
Condensate pipeFreezing weather, gurgling from the boiler, the plastic pipe outsideThaw it with warm (not boiling) water or a hot water bottle.

Both manuals ask you to check the pressure monthly. Low pressure shows as F.22, which is cleared by filling the system, not by the reset button. Our guide to Glow-worm boiler pressure covers the filling loop.

If you can smell gas, do not press reset or use electrical switches. Turn off the gas at the meter if it is safe to do so, open doors and windows, leave the property and call the National Gas Emergency Service on 0800 111 999.

How to reset a Glow-worm Energy7

The fault table in the Energy7 operating instructions (page 14) gives the action for an ignition fault as "Press the reset button for one second." The boiler then tries to light again.

  1. Write down the code exactly as shown, for example F.28.
  2. Complete the checks above.
  3. Press the reset key for about one second. Holding it longer does nothing extra.
  4. Wait a few minutes while the boiler runs its start-up sequence.
  5. If the code returns, try again, but stop after three attempts in total.

F.83 and the 45 minute wait

For F.83, which the instructions describe as a fault in the product, you press reset as normal. If it persists after one more reset, the boiler starts a 45 minute anti-cycling period and shows S.54 (pages 14 and 15). That is not a new fault, so let the 45 minutes run out rather than pressing reset again. If F.83 is still there afterwards, the manual says to consult a competent person.

How to reset a Glow-worm Betacom 4

The Betacom 4 has no separate reset key. Its operating instructions put reset on the on/off button, numbered 2 on the control panel diagram (page 9, fault table pages 15 and 16).

  1. Note the code. F.28 and F.22 are the two you are most likely to see.
  2. For F.22, fill the system to 1.0 to 1.5 bar. Glow-worm says to contact a competent person if the pressure drops often.
  3. For F.28, press the on/off button to make the boiler try to light again.
  4. Run a hot tap or turn up the thermostat so it has a reason to fire.
  5. If F.28 is still there after three attempts, contact a competent person.

The same button controls standby: a press of under three seconds switches the boiler to standby and the display shows OFF. If that happens, press it again to switch back on.

Codes a reset can and cannot fix

Both manuals say to contact a competent person about fault codes in general. In practice a few codes can be reset once an obvious cause is dealt with, and others need an engineer from the start.

CodeMeaningReset?Notes
F.22Low water pressure in the heating systemFill the system firstFrequent topping up means a leak or vessel fault.
F.28Boiler failed to light after three ignition attemptsYes, up to three timesCheck gas, prepayment credit and the condensate pipe first. See our Glow-worm F28 guide.
F.29Flame lost while the boiler was runningTwo or three times at mostOften a gas supply interruption or a condensate problem.
F.75Pressure sensor fault, mainly on the Energy rangeOnce or twice after checking pressureRepeats point to the pump or sensor.
F.83 (Energy7)Fault in the productOnce, then wait out S.54Glow-worm says consult a competent person if it persists.

Repeated ignition or flame codes, and codes pointing to the fan, gas valve or overheat protection, need a Gas Safe registered engineer after one or two resets. If a video suggests resetting an overheat cut-out inside the casing, ignore it: that is engineer-only work.

How to turn the heating on after a reset

After a reset the boiler returns to its last operating mode. If the radiators stay cold, check the mode. The Energy7 and Betacom 4 instructions (page 11 of each) say to press the mode button repeatedly until the display shows the one you want:

  • Heating and hot water
  • Heating only
  • Hot water only
  • No requirement

Choose heating and hot water, or heating only, then check the room thermostat is above room temperature and the timer is in an on period. If your Betacom 4 has a front timer, its instructions (page 10) describe position I as permanently on and 0 as permanently off, a quick way to rule the timer out. Check wireless thermostat batteries too.

After the reset: limits, engineers and prevention

If the same code returns within minutes or hours of a reset, the cause is still there. Glow-worm's limit of three attempts for ignition faults is the most we would use for any code, and fewer for flame or fan codes, because repeated resets can hide a worsening fault.

Call a Gas Safe registered engineer if:

  • the code returns after three resets, or straight after a reset
  • gas, power, pressure and the condensate pipe all check out but it still will not light
  • you are topping up the pressure every few weeks
  • there is water under the boiler, an unusual noise or scorch marks

Call-out and diagnosis typically costs £60 to £150. Never remove the casing yourself. Tell the engineer the model, the code and how many resets you tried.

To prevent repeat lockouts, book an annual service (typically £80 to £150) and check, as Glow-worm asks, that the condensate pipe and tundish stay clear. Insulating an outside condensate pipe helps in frost. Leave the boiler in standby rather than off at the spur, because the Energy7 instructions note that frost protection stays active in standby.

Frequently asked questions

Where is the reset button on a Glow-worm Energy7?

The Energy7 has its own reset key on the control panel, which Glow-worm's operating instructions call the fault clearance key. Press it for about one second after checking the gas, power, pressure and condensate pipe.

How long do I press the Glow-worm reset button for?

About one second. Glow-worm's Energy7 instructions say to press the reset button for one second, after which the boiler makes another ignition attempt. Holding it down longer does not help.

Does a Glow-worm Betacom 4 have a separate reset button?

No. On the Betacom 4 the reset function is on the on/off button, numbered 2 on the control panel diagram in the operating instructions. A short press of under three seconds also puts it into standby, so press again if the display shows OFF.

How many times can I reset a Glow-worm boiler before calling someone?

Glow-worm's Energy7 and Betacom 4 instructions say to consult a competent person if an ignition fault has not cleared after three reset attempts. For a gas boiler that means a Gas Safe registered engineer.

Why does my Glow-worm Energy7 show S.54 after a reset?

S.54 is a 45 minute anti-cycling period. On the Energy7 it starts if F.83 is still present after one more reset, and you should wait for it to finish rather than pressing reset again.

Sources

How the prices on this page were put together: typical UK prices for the parts and labour involved, shown as ranges rather than quotes. In October 2026 we compared them with the published UK price guides from Checkatrade, MyBuilder, MyJobQuote and Fantastic Services. Prices vary by area, boiler model and engineer, so always ask for a written quote.

Fault code meanings can differ between boiler models and software versions. Always check the user manual for your exact model. This page is general information, not a substitute for an inspection by a Gas Safe registered engineer. Read our disclaimer.