Resetting a current Glow-worm combi takes one short press of one button, but only after you have dealt with whatever made it lock out. Glow-worm allows three attempts for an ignition fault; after that it is a job for a Gas Safe registered engineer. For other brands, see our guide on how to reset a boiler safely.
Which Glow-worm boiler do you have?
The reset method differs between ranges, so find the model name first. It is normally printed on the front of the boiler and on the user instructions.
- Energy7 combi (25c-A, 30c-A, 35c-A): Glow-worm's Energy7 operating instructions, document 0020300878_00 (March 2020). It has a dedicated reset key, which the manual calls the fault clearance key.
- Betacom 4 combi (24c-A, 30c-A): the Betacom 4 operating instructions, document 0020238423_02 (August 2019). Reset is on the on/off button.
- Ultracom, Easicom, Flexicom, Micron and older models: earlier control panels with different buttons, lights and code lists. We have not checked their manuals for this page, so follow the user instructions for your exact boiler, which Glow-worm publishes on its website.
Our Glow-worm fault code hub lists the codes we cover for each range.
Checks to make before you press reset
A reset only tells the boiler to try again. If the cause is still there, it locks out again and you have used up an attempt for nothing.
| Check | What to look for | What to do |
|---|---|---|
| Gas supply | Does the hob or gas fire light? Is there credit on a prepayment meter? | Top up. If nothing on gas works and you have credit, call your supplier. |
| Gas isolation valve | The handle on the gas pipe under the boiler | It should sit in line with the pipe; turn it back if it is across. |
| Power | Is the display lit? Has the fused spur or a circuit breaker tripped? | Switch the spur back on or reset the breaker. |
| System pressure | The pressure gauge or reading on the display | Betacom 4: 1.0 to 1.5 bar. Energy7: within 0.5 to 2.7 bar. Top up with the filling loop if low. |
| Condensate pipe | Freezing weather, gurgling from the boiler, the plastic pipe outside | Thaw it with warm (not boiling) water or a hot water bottle. |
Both manuals ask you to check the pressure monthly. Low pressure shows as F.22, which is cleared by filling the system, not by the reset button. Our guide to Glow-worm boiler pressure covers the filling loop.
If you can smell gas, do not press reset or use electrical switches. Turn off the gas at the meter if it is safe to do so, open doors and windows, leave the property and call the National Gas Emergency Service on 0800 111 999.
How to reset a Glow-worm Energy7
The fault table in the Energy7 operating instructions (page 14) gives the action for an ignition fault as "Press the reset button for one second." The boiler then tries to light again.
- Write down the code exactly as shown, for example F.28.
- Complete the checks above.
- Press the reset key for about one second. Holding it longer does nothing extra.
- Wait a few minutes while the boiler runs its start-up sequence.
- If the code returns, try again, but stop after three attempts in total.
F.83 and the 45 minute wait
For F.83, which the instructions describe as a fault in the product, you press reset as normal. If it persists after one more reset, the boiler starts a 45 minute anti-cycling period and shows S.54 (pages 14 and 15). That is not a new fault, so let the 45 minutes run out rather than pressing reset again. If F.83 is still there afterwards, the manual says to consult a competent person.
How to reset a Glow-worm Betacom 4
The Betacom 4 has no separate reset key. Its operating instructions put reset on the on/off button, numbered 2 on the control panel diagram (page 9, fault table pages 15 and 16).
- Note the code. F.28 and F.22 are the two you are most likely to see.
- For F.22, fill the system to 1.0 to 1.5 bar. Glow-worm says to contact a competent person if the pressure drops often.
- For F.28, press the on/off button to make the boiler try to light again.
- Run a hot tap or turn up the thermostat so it has a reason to fire.
- If F.28 is still there after three attempts, contact a competent person.
The same button controls standby: a press of under three seconds switches the boiler to standby and the display shows OFF. If that happens, press it again to switch back on.
Codes a reset can and cannot fix
Both manuals say to contact a competent person about fault codes in general. In practice a few codes can be reset once an obvious cause is dealt with, and others need an engineer from the start.
| Code | Meaning | Reset? | Notes |
|---|---|---|---|
| F.22 | Low water pressure in the heating system | Fill the system first | Frequent topping up means a leak or vessel fault. |
| F.28 | Boiler failed to light after three ignition attempts | Yes, up to three times | Check gas, prepayment credit and the condensate pipe first. See our Glow-worm F28 guide. |
| F.29 | Flame lost while the boiler was running | Two or three times at most | Often a gas supply interruption or a condensate problem. |
| F.75 | Pressure sensor fault, mainly on the Energy range | Once or twice after checking pressure | Repeats point to the pump or sensor. |
| F.83 (Energy7) | Fault in the product | Once, then wait out S.54 | Glow-worm says consult a competent person if it persists. |
Repeated ignition or flame codes, and codes pointing to the fan, gas valve or overheat protection, need a Gas Safe registered engineer after one or two resets. If a video suggests resetting an overheat cut-out inside the casing, ignore it: that is engineer-only work.
How to turn the heating on after a reset
After a reset the boiler returns to its last operating mode. If the radiators stay cold, check the mode. The Energy7 and Betacom 4 instructions (page 11 of each) say to press the mode button repeatedly until the display shows the one you want:
- Heating and hot water
- Heating only
- Hot water only
- No requirement
Choose heating and hot water, or heating only, then check the room thermostat is above room temperature and the timer is in an on period. If your Betacom 4 has a front timer, its instructions (page 10) describe position I as permanently on and 0 as permanently off, a quick way to rule the timer out. Check wireless thermostat batteries too.
After the reset: limits, engineers and prevention
If the same code returns within minutes or hours of a reset, the cause is still there. Glow-worm's limit of three attempts for ignition faults is the most we would use for any code, and fewer for flame or fan codes, because repeated resets can hide a worsening fault.
Call a Gas Safe registered engineer if:
- the code returns after three resets, or straight after a reset
- gas, power, pressure and the condensate pipe all check out but it still will not light
- you are topping up the pressure every few weeks
- there is water under the boiler, an unusual noise or scorch marks
Call-out and diagnosis typically costs £60 to £150. Never remove the casing yourself. Tell the engineer the model, the code and how many resets you tried.
To prevent repeat lockouts, book an annual service (typically £80 to £150) and check, as Glow-worm asks, that the condensate pipe and tundish stay clear. Insulating an outside condensate pipe helps in frost. Leave the boiler in standby rather than off at the spur, because the Energy7 instructions note that frost protection stays active in standby.