Smell gas? Turn off the gas at the meter, open windows, do not use switches and call the National Gas Emergency Service on 0800 111 999.

Ideal Boiler No Hot Water: What to Check on a Logic Combi

Quick answer

Ideal's own advice is to check the power, gas or prepayment credit, water supply, hot water temperature setting and timer first, then the pressure gauge, which should read 1 to 1.5 bar. A Logic Combi2 will not run at all below 0.3 bar, and a frozen condensate pipe will lock it out with L02. If a code returns after a restart, call a Gas Safe registered engineer, or Ideal if the boiler is still under warranty.

On this page
  1. Quick checks Ideal recommends first
  2. No hot water only, or no heating either?
  3. Check the pressure on the gauge
  4. Ideal fault codes that stop the hot water
  5. Frozen condensate pipe on a Logic Combi2
  6. Causes the basic checks will not fix
  7. Restarting, warranty and calling an engineer

An Ideal boiler with no hot water usually has one of a handful of problems: no power, no gas, the wrong setting, low pressure, a lockout code or a frozen condensate pipe. You can check all of these in a few minutes before paying for an engineer.

We have based this guide on Ideal's help article "No Hot Water? Here's What to Do", the Logic Combi2 C24, C30 and C35 user guide (UIN 236183 A01, February 2023) and Ideal's Logic Combi troubleshooting page. If only the taps are cold, our guide to no hot water but heating works covers other brands too.

Quick checks Ideal recommends first

  • Power. No lights or display? Check the boiler's switch or breaker at the consumer unit has not tripped.
  • Gas credit. Check any prepayment meter balance and top up.
  • Water supply. If no water comes from any tap, the cause is the mains (roadworks or a frozen pipe), not the boiler.
  • Hot water temperature. Ideal says water set below 30°C will feel quite cold. The Logic Combi2 hot water knob (A) runs from about 40°C to a maximum of 65°C.
  • Timer. A power cut or clock change can reset a timer. This affects system and heat only boilers that heat a cylinder on a schedule, not combis.
  • Recent baths. A cylinder emptied by a long bath needs time; Ideal suggests giving it an hour.

No hot water only, or no heating either?

Ideal's first diagnostic step is to feel a radiator and see whether the boiler fires when the heating is switched on.

What you findWhat it suggests
Radiators cold and the boiler will not fire for heatingA boiler-wide problem: power, gas, pressure or a lockout code. Ideal says call an engineer if it will not fire once the basics are checked.
Radiators warm, hot taps cold (combi)Often the diverter valve, which switches the boiler between heating and hot water.
Cold water runs from the hot taps on a combiWater is reaching the tap, so it is not a supply blockage. The boiler is simply not heating it.
Cylinder cold (system or heat only boiler)A timer, cylinder thermostat or boiler problem.

For a diverter valve that may be stuck, Ideal suggests turning the hot taps on and off a few times while the central heating is on. If that does not free it, an engineer needs to repair or replace it.

Check the pressure on the gauge

Ideal's help article and the Logic Combi2 user guide (page 6) both give 1 to 1.5 bar as the pressure to aim for, and the user guide states the boiler will not operate below 0.3 bar. That is a common reason for hot water to stop without warning.

  1. Read the gauge (G on the Logic Combi2 panel) with the boiler cold.
  2. If it is below 1 bar, top up through the filling loop to 1 to 1.5 bar, then close both valves fully.
  3. If it is too high, Ideal suggests bleeding a radiator.
  4. If a code is showing, press restart once the pressure is right.

Low pressure shows as F1 on Logic Combi boilers; our Ideal F1 guide covers it in detail. If the pressure keeps falling, Ideal's troubleshooting page says there may be a leak and to contact a Gas Safe registered engineer.

Ideal fault codes that stop the hot water

Ideal's article asks you to check the display and look up any message in your handbook. These are the codes on the Logic Combi range most likely to leave you without hot water, with the first step Ideal gives on its troubleshooting page or in the user guide.

CodeMeaningFirst step
F1Low water pressureRepressurise to 1 to 1.5 bar.
F2Flame lossCheck other gas appliances work, the gas is on at the meter and any prepayment meter has credit.
F3Fan faultRestart the boiler.
F4 or L4Flow thermistorRestart the boiler.
L2Ignition lockout, the boiler failed to lightCheck the gas supply and condensate pipe, then restart.
L02 (Logic Combi2)Condensate blockageThaw the condensate pipe if it is frozen, then restart.

We cover the ignition lockout in more depth in our Ideal L2 guide. Codes that come straight back after a restart, and any code linked to the fan, a sensor or the control board, need a Gas Safe registered engineer.

Frozen condensate pipe on a Logic Combi2

In a cold snap, the plastic condensate pipe that drains water from the boiler can freeze where it runs outside. The Logic Combi2 user guide (page 7) describes the sequence: condensate backs up, the boiler gurgles, and then it locks out with L02. Hot water stops along with the heating.

  • Find the condensate pipe where it leaves the house. It is usually a white or grey plastic pipe running to a drain.
  • Thaw it with a warm (not boiling) source, such as a hot water bottle or warm water from a watering can.
  • Ideal's guide says not to thaw pipework above ground level, so work only on sections you can reach from the ground.
  • Once it is clear, press the restart button.

To help prevent it, the guide suggests turning the central heating knob (B) to maximum during cold weather and returning it to your normal setting afterwards. Keep the power on too: frost protection on the Logic Combi2 runs the boiler when the water inside falls below 5°C.

Causes the basic checks will not fix

Combi boilers

If the boiler fires for heating but not hot water, the likely parts are the diverter valve, the plate heat exchanger (which heats the tap water) or the flow sensor that detects an open tap. Very low mains flow can also stop the boiler recognising a demand. For lukewarm water, the Logic Combi2 guide notes that flow rate affects tap temperature, so try a gentler flow. Still lukewarm with the knob at 65°C? Have the plate heat exchanger and diverter valve checked.

System and heat only boilers

Here hot water depends on the timer, the cylinder thermostat and a motorised valve. If the heating works but the cylinder stays cold during an on period, suspect the cylinder thermostat or motorised valve. An immersion heater, if fitted, gives you hot water while you wait.

JobTypical UK cost
Engineer call-out and diagnosisTypically £60 to £150
Diverter valve, full replacementTypically £200 to £450
Plate heat exchangerTypically £200 to £450
Motorised or zone valveTypically £180 to £300
Minor repair (sensor or wiring)Typically £100 to £180

Diverter valves, plate heat exchangers, flow sensors and control boards all sit inside the casing. Testing and replacing them is a job for a Gas Safe registered engineer, never a homeowner.

Restarting, warranty and calling an engineer

The Logic Combi2 restart button is marked F. The user guide says the boiler shows a fault code if it fails to light after five attempts, and that you press restart when a code tells you to. Do this two or three times at most, then contact a Gas Safe registered engineer.

Older Ideal boilers, roughly pre-2004, may have a pilot light. Relight it only as the handbook for that model describes, and if it will not stay lit, book a Gas Safe registered engineer.

Under warranty, Ideal's troubleshooting page says to contact Ideal. The Logic Combi2 guide warns a visit charge may apply if the fault is not with the boiler, so do the checks first. Out of warranty, any Gas Safe registered engineer can help, and Ideal recommends a yearly service. Other codes are on our Ideal boiler fault code hub.

Frequently asked questions

Why has my Ideal Logic combi stopped giving hot water after a frosty night?

The most likely cause is a frozen condensate pipe. Ideal's Logic Combi2 user guide says the boiler gurgles and then locks out with L02, so thaw the outside pipe with warm (not boiling) water and press restart.

Will an Ideal Logic Combi2 still make hot water if the pressure is low?

Not once it drops too far. The Logic Combi2 user guide says the boiler will not operate below 0.3 bar, and Ideal recommends topping up to 1 to 1.5 bar with the filling loop.

How hot can the hot water get on an Ideal Logic Combi2?

The hot water knob runs from about 40°C to 65°C, and the boiler limits it to 65°C. Ideal notes that water set below 30°C on any of its boilers will feel quite cold.

Can a stuck diverter valve stop hot water on an Ideal combi?

Yes. Ideal lists a stuck divertor valve as a possible cause and suggests turning the hot taps on and off a few times while the heating is on. If that does not free it, a Gas Safe registered engineer needs to repair or replace it.

Should I call Ideal or a local engineer about no hot water?

If the boiler is under warranty, contact Ideal first. Otherwise book a Gas Safe registered engineer, but do the basic checks before either, as Ideal's user guide says a visit charge may apply if the fault is not with the boiler.

Sources

How the prices on this page were put together: typical UK prices for the parts and labour involved, shown as ranges rather than quotes. In October 2026 we compared them with the published UK price guides from Checkatrade, MyBuilder, MyJobQuote and Fantastic Services. Prices vary by area, boiler model and engineer, so always ask for a written quote.

Fault code meanings can differ between boiler models and software versions. Always check the user manual for your exact model. This page is general information, not a substitute for an inspection by a Gas Safe registered engineer. Read our disclaimer.