Smell gas? Turn off the gas at the meter, open windows, do not use switches and call the National Gas Emergency Service on 0800 111 999.Smell gas? Call 0800 111 999

Steam Coming From Your Boiler Flue: Normal or a Problem?

Quick answer

Steam or a white cloud from your boiler flue is normal for a condensing boiler, especially in cold weather: it is water vapour from burning gas, and almost every gas boiler fitted in Great Britain since the mid-2000s is a condensing type. Call a Gas Safe registered engineer if the plume is dark or smoky, smells of fumes or leaves soot, or if steam or water is coming from the boiler itself rather than the flue.

On this page
  1. Why a condensing boiler makes a plume
  2. Normal plume or warning sign?
  3. The warning signs in more detail
  4. Plume management kits
  5. When to call an engineer, and typical costs

Why a condensing boiler makes a plume

Burning natural gas produces carbon dioxide and water vapour. A condensing boiler recovers extra heat from its exhaust by cooling it in the heat exchanger, which is why it is more efficient than older boilers. Some of the water vapour condenses inside the boiler and drains away as condensate. The rest leaves through the flue as warm, moist air.

When that air meets cold outside air, the vapour condenses into tiny droplets, just like your breath on a winter morning. The result is a white plume that can look like steam or smoke. It is usually most noticeable:

  • on cold, damp or still days, when the plume hangs around instead of dispersing
  • when the boiler first fires up, or while it is working hard to heat the house or hot water
  • where the flue points into a sheltered corner, a narrow side passage or under a canopy

Condensing flues are designed to slope back towards the boiler, so condensate runs back into it rather than out of the terminal. A persistent drip from the end of the flue can mean it was not fitted at the right angle, which is worth mentioning to an engineer at the next service.

Normal plume or warning sign?

What you seeNormal or a warning?What to do
White, wispy plume that disappears within a metre or twoNormalNothing
Heavier white plume in cold or damp weatherNormalNothing, or consider a plume kit if it is a nuisance
Plume drifting onto a neighbour's window, a path or a car portNormal, but a nuisanceAsk an engineer about a plume management kit
Plume blowing back in through your own window or ventWarningKeep the opening closed and call a Gas Safe engineer
Dark, grey or black smokeWarningTurn the boiler off and call a Gas Safe engineer
Soot or black staining around the flue terminalWarningTurn the boiler off and call a Gas Safe engineer
Smell of fumes or burning, indoors or outWarningTurn the boiler off, ventilate and call a Gas Safe engineer
Steam or water escaping from the boiler casing or indoor flue jointsWarningTurn the boiler off and call a Gas Safe engineer
Damaged, loose or disconnected flueWarningStop using the boiler and call a Gas Safe engineer

If your carbon monoxide alarm sounds, or anyone has headaches, dizziness or nausea that ease when they leave the house, open windows, turn off the boiler, get outside and call the National Gas Emergency Service on 0800 111 999 (0800 002 001 in Northern Ireland). Our guide on what to do when a carbon monoxide alarm is going off covers the steps in full.

The warning signs in more detail

Smoke, soot and staining

A gas boiler that is burning properly should not produce smoke or soot. Dark exhaust, black marks around the terminal or staining on the wall above it suggest poor combustion, which can also mean carbon monoxide is being produced. Stop using the boiler and book a Gas Safe registered engineer.

Steam or water from the boiler itself

Steam, hissing or water from the casing, or from flue joints inside the house, is not the normal plume. It can mean a leak onto hot parts, a failed seal or a flue section that has come apart. Turn the boiler off and call an engineer. If water is dripping from underneath the boiler, see our guide to a boiler leaking water.

Flue damage or blockage

Look at the flue terminal from the ground or a window without touching it. Birds' nests, ivy, a cracked or loose terminal, or a flue that has been boxed in or had a structure built close to it can stop fumes clearing properly. Many boilers shut down with a flue or overheat code, such as Worcester Bosch E9 224, when something is wrong. Never try to clear, move or repair the flue yourself.

Condensate problems in freezing weather

The water that condenses inside the boiler drains through a separate condensate pipe. In a hard frost that pipe can freeze and cause a lockout, which is a different issue from the plume. Our frozen condensate pipe guide explains how to thaw it safely with warm (not boiling) water.

Plume management kits

If the plume is harmless but annoying, for example because it drifts onto a neighbour's window, a doorway, a path or a patio, a plume management kit can redirect it. The kit is an extension fitted to the flue terminal that carries the exhaust through a separate pipe and releases it higher up or further from the problem area, usually through an elbow that points it upwards.

  • Kits are specific to each manufacturer and flue system. Worcester Bosch, Vaillant, Ideal, Baxi, Glow-worm, Viessmann and Vokera all make their own, and the kit must match your boiler and flue.
  • The installation has to follow the manufacturer's instructions, including maximum pipe lengths and minimum distances from windows, doors, air bricks, gutters and boundaries.
  • Only a Gas Safe registered engineer should fit one, because it becomes part of the flue.
  • A terminal guard is usually needed where a flue outlet is low enough for people to touch, commonly below 2 metres above ground that people walk on.

A plume kit can also help when a new boiler has to go in a spot where the terminal would otherwise be too close to an opening window or a boundary. The engineer will check what the manufacturer allows for your model.

When to call an engineer, and typical costs

Call a Gas Safe registered engineer if you see any of the warning signs above, if the plume is getting back into the house, or if the boiler keeps locking out. The flue should also be checked at every annual service, which includes a flue gas analysis to confirm the boiler is burning cleanly. Our boiler service cost guide explains what a service covers.

JobTypical UK cost
Plume management kit, parts onlyTypically £50 to £150
Plume kit supplied and fittedTypically £150 to £350
Flue terminal guard supplied and fittedTypically £60 to £150
Engineer visit to check combustion and the flueTypically £60 to £120
Flue section repaired or replacedTypically £150 to £400

Costs sit at the lower end for a short kit fitted to an easy ground floor flue outside London. They rise for longer kits and extra bends, brand-specific parts, flues that need a tower or scaffolding to reach safely, and London labour rates. If a plume kit is fitted as part of a new boiler installation, the extra cost is usually lower than booking a separate visit later.

Frequently asked questions

Is it normal for steam to come out of a boiler flue?

Yes. Condensing boilers release water vapour that forms a white plume in cold air. It is harmless as long as it is white, clears quickly and there is no soot, smoke or fume smell.

Why is there more steam from my boiler in winter?

Cold, damp air makes the water vapour condense into visible droplets, and the boiler also runs harder in winter. Both make the plume larger and longer lasting.

Is smoke from a boiler flue dangerous?

Dark smoke or soot is a warning sign of poor combustion, which can produce carbon monoxide. Turn the boiler off and call a Gas Safe registered engineer.

Can I fit a plume management kit myself?

No. The kit becomes part of the flue and must be fitted by a Gas Safe registered engineer, using the kit made for your boiler.

My neighbour complains about my boiler plume. What can I do?

Ask a Gas Safe registered engineer whether a plume management kit can redirect it away from their property. The engineer will also check the flue meets the manufacturer clearance rules.

Fault code meanings can differ between boiler models and software versions. Always check the user manual for your exact model. This page is general information, not a substitute for an inspection by a Gas Safe registered engineer. Read our disclaimer.