Worcester Bosch Fault 1021: Hot Water Temperature Sensor Fault

Quick answer

Fault 1021 on a Worcester Bosch Greenstar 8000 Life means the boiler has detected a fault with its hot water (or cylinder charging) temperature sensor. It is a blocking code, so the boiler holds off rather than locking out. Check the power and your hot water settings, but the sensor, its plug and the wiring need testing by a Gas Safe registered engineer.

On this page
  1. What fault 1021 means
  2. A blocking code, not a lockout
  3. Other four-digit codes on the 8000 Life
  4. What causes fault 1021
  5. Checks you can make yourself
  6. What to tell the engineer
  7. Typical repair costs in the UK

What fault 1021 means

Fault 1021 means your Worcester Bosch boiler cannot get a sensible reading from the sensor that measures hot water temperature. Worcester's installation and maintenance instructions for the Greenstar 8000 Life gas fired condensing combi (document 6720883865, 2021/11 edition, section 10.1.2) list 1021 as "Cylinder charging or hot water temperature sensor faulty". The earlier 2019/02 edition of the same manual puts it more simply: "Hot water temperature sensor is defective".

If your copy is the 2019 print, you will find the code in the fault table on pages 62 to 63 with the shorter wording. In the 2021 print it sits in the table that runs from page 75 to page 79. Both describe the same fault and share the same document number, so either edition applies.

The models in those manuals are the GR8300iW C combis (30, 35, 40, 45 and 50 C). On a combi there is no cylinder to charge, so in practice the code refers to the domestic hot water temperature sensor. The combined wording appears because the same fault table is written to cover both set-ups.

What you are likely to notice

The boiler uses this sensor to control the temperature of the water coming out of your taps. With no reliable reading it cannot do that properly, so most people notice the code alongside a hot water problem, such as water that stays cold, runs too hot or changes temperature. Write down exactly what the taps are doing, as it helps the engineer.

A blocking code, not a lockout

The 8000 Life table marks 1021 with the letter B, a blocking fault. In Worcester's manuals a blocking fault stops the boiler without the usual lockout, and it usually clears by itself once the cause goes away. The Greenstar i manuals also note that some blocking faults turn into locking faults if they last long enough. So 1021 may come and go, which often points to a loose plug or a sensor on its way out rather than one that has failed completely.

Other four-digit codes on the 8000 Life

The Greenstar 8000 Life uses four-digit fault numbers, and a few near 1021 are easy to mix up.

CodeManual wordingWho deals with it
1017"System pressure too low"You first, by topping up the pressure
1018"Maintenance interval expired"Your engineer, at the next service
1019"Incorrect pump type detected"Gas Safe engineer
1021"Cylinder charging or hot water temperature sensor faulty"Gas Safe engineer

1021 is also unrelated to A21, which comes from Worcester's heating controls rather than the boiler.

What causes fault 1021

The remedies in the 2021 manual give three causes, in the order an engineer checks them.

Sensor or plug not connected

The first step is to check the hot water temperature sensor is connected and its plug is properly fitted. A plug that has worked loose, perhaps after a repair nearby, can break the reading on and off.

Sensor out of range

The sensor works by changing its electrical resistance with temperature. The manual tells engineers to measure that resistance and replace the sensor if it is wrong. This is the most common outcome when the code stays on all the time.

Damaged wiring harness

The last check is continuity of the harness between the sensor and the boiler's electronics. A broken or chafed wire gives the same symptom as a failed sensor, so it is tested before parts are swapped.

Checks you can make yourself

  1. Note the code 1021 and what the hot taps are doing. Check whether heating still works too.
  2. Check the fused spur feeding the boiler is on, and whether the fault followed a power cut.
  3. Look at your hot water settings on the boiler display or app, in case something has been changed.
  4. Look underneath the boiler, without opening it, for drips or water. Mention anything you see.
  5. Reset as the 8000 Life user instructions describe if the code does not clear by itself, no more than two or three times.

Our Worcester boiler no hot water guide covers other reasons a Worcester combi stops heating your taps, and our Worcester boiler reset guide explains when a reset is worth trying.

The sensor and its wiring are inside the casing, next to hot pipework and mains-powered electronics. Do not remove the casing or unplug anything. Testing and replacing the sensor is work for a Gas Safe registered engineer.

What to tell the engineer

Give the engineer the code 1021, the exact model (for example GR8300iW 40 C), whether the code is constant or comes and goes, and what the hot water does when it appears. Mention any recent work on the boiler, as that points towards a disturbed plug. An engineer who knows it is the hot water sensor can usually check the plug, resistance and harness in one visit.

Expect the engineer to isolate the power before opening the case, check the plug on the sensor first, then measure the sensor's resistance and compare it with Worcester's figures. Only if the sensor reads correctly will they move on to testing the harness. Working in that order avoids paying for a new sensor when the real fault is a loose connector or a damaged wire.

Typical repair costs in the UK

JobTypical UK cost
Engineer call-out and diagnosisTypically £60 to £150
Refitting a loose plug or repairing the sensor wiringTypically £100 to £180
Hot water temperature sensor (NTC thermistor) replacementTypically £100 to £200

Sensor faults are among the cheaper boiler repairs. If the harness or plug is the cause, the cost may be at the lower end.

Frequently asked questions

What does fault 1021 mean on a Worcester Greenstar 8000 Life?

Worcester's manual lists 1021 as a faulty cylinder charging or hot water temperature sensor. On the 8000 Life combis this is the sensor that measures the water going to your taps.

How do I fix fault 1021 on a Worcester boiler?

Check the power and your hot water settings, then reset if the code does not clear. If 1021 stays, a Gas Safe registered engineer needs to check the sensor plug, its resistance and the wiring harness.

How do I reset the 1021 error code on a Worcester boiler?

1021 is a blocking code, so it usually clears once the sensor reads properly again. If it does not, reset as the 8000 Life user instructions describe, no more than two or three times.

Can Worcester fault 1021 stop my hot water?

It often affects hot water, because the boiler uses this sensor to control tap temperature. Note what the taps are doing and tell your engineer.

Sources

The meaning of 1021 on this page comes from these manufacturer documents:

Codes and their meanings can change between models and software versions, so the manual for your exact boiler always comes first. Documents with a link open on the manufacturer's own website.

How the prices on this page were put together: typical UK prices for the parts and labour involved, shown as ranges rather than quotes. In October 2026 we compared them with the published UK price guides from Checkatrade, MyBuilder, MyJobQuote and Fantastic Services. Prices vary by area, boiler model and engineer, so always ask for a written quote.

Other Worcester Bosch fault codes

Full list →

Fault code meanings can differ between boiler models and software versions. Always check the user manual for your exact model. This page is general information, not a substitute for an inspection by a Gas Safe registered engineer. Read our disclaimer.