Boiler Has No Power or a Blank Display: What to Check

Quick answer

A boiler with no lights and a blank display has usually lost its electrical supply. Check the rest of the house has power, the fused spur next to the boiler is switched on, the fuse in it has not blown and nothing has tripped at the consumer unit. If power is reaching the boiler and it is still dead, the fault is inside (often an internal fuse or the circuit board), which needs a Gas Safe registered engineer.

On this page
  1. First, is it really a power fault?
  2. Check the fused spur
  3. Check the consumer unit
  4. When the fault is inside the boiler
  5. Quick checklist
  6. Typical repair costs in the UK

First, is it really a power fault?

Before assuming the worst, rule out the simple explanations. Some boilers dim or switch off the display after a period with no activity to save energy, and the screen wakes up when you press a button. On others the display shows very little in standby. Check the manual for your model to see what a normal standby screen looks like.

Then check the power more widely:

  • Are other lights and sockets in the house working? If nothing works, it is a power cut or a problem with your main supply, not the boiler.
  • If you have a separate timer, programmer or wireless thermostat receiver, is it showing anything? In many homes the controls share the boiler supply, so if they are dead too, power to the heating has gone.
  • Does a smart thermostat hub near the boiler have no lights? That is another sign the supply is missing.

Check the fused spur

Most boilers are wired into a fused connection unit, usually called a fused spur. It is a square switch plate on the wall near the boiler, often with a red neon light and a small fuse holder on the front. Some are labelled "Boiler" or "Central heating". On older installations it may be in an airing cupboard or next to the hot water cylinder.

  1. Check the switch is on. Spurs sometimes get knocked off by accident, or switched off during decorating and forgotten.
  2. If the switch is on but the neon light is off, the fuse may have blown or the circuit may be off at the consumer unit.
  3. To check the fuse, switch the spur off first. Pull out the fuse carrier (a small flat-head screwdriver helps ease it out), remove the cartridge fuse and fit a new one of the same rating. Boilers are commonly on a 3 amp fuse, but always match the rating printed on the old fuse or in the installation manual.
  4. Refit the carrier, switch the spur back on and see whether the display returns.

A few boilers are connected with a normal plug instead. In that case the fuse is in the plug top: switch off and unplug it, change the fuse for one of the same rating and plug it back in.

Only check the fuse in the spur or plug top. Never open the boiler casing to look at the internal fuses, wiring or circuit board. If a new fuse blows straight away, do not keep replacing it. That means a fault is drawing too much current, and it needs an engineer.

Check the consumer unit

The consumer unit (fuse box) is usually near the front door, under the stairs or in a garage. Look for a switch that has dropped to the off position. The breaker for the boiler might be labelled "Boiler" or "Heating", or the boiler may share a general sockets or lighting circuit.

  • If a single circuit breaker (MCB) has tripped, switch it back on once.
  • If a larger RCD switch has tripped and taken out several circuits, switch it back on once.
  • If it trips again, leave it off. Switch the boiler spur off, then try the breaker again. If it now stays on, the fault is probably in the boiler or its wiring and needs a Gas Safe registered engineer. If it still trips with the boiler isolated, call an electrician.

Water can cause trips too. A leak dripping onto wiring or into the spur, or condensation in a cold loft, can make an RCD trip. If you see water near the electrics, keep the power off and get it checked. Our guide to a boiler leaking water explains what to look for.

When the fault is inside the boiler

If the spur light is on, the breaker is on and the boiler is still dead, power is reaching the boiler but not getting through. Typical internal causes include:

  • a blown fuse on the main circuit board, often after a power surge, a thunderstorm or a fault in another part such as the pump or fan
  • a failed printed circuit board (PCB) or its power supply section
  • a faulty display board or its connecting cable, where the boiler may still run but the screen stays blank
  • loose or damaged wiring between the spur and the boiler
  • water damage to the electrics from an internal leak

All of these are jobs for a Gas Safe registered engineer. The engineer will check the incoming supply, test the internal fuses and components and find out why a fuse blew before replacing it, because a new fuse on its own often blows again. If the PCB is failing but still partly working, you may see board faults such as Ideal F9 or Vaillant F63 instead of a blank screen.

Quick checklist

CheckWhat you are looking forNext step
Power elsewhere in the houseOther lights and sockets workingIf nothing works, report a power cut by calling 105
Display standby modeScreen wakes when you press a buttonNothing to fix
Fused spur switch and neonSwitch on, light litSwitch on, or check the fuse
Fuse in the spur or plug topFuse intactReplace with the same rating, once
Consumer unitNo tripped MCB or RCDReset once, electrician if it trips again
Thermostat and timerCalling for heat, batteries not flatReplace batteries or adjust settings

Typical repair costs in the UK

JobTypical UK cost
Replacement cartridge fuse for a spur or plugA few pounds
Engineer call-out and diagnosisTypically £60 to £120
Internal fuse replaced and cause foundTypically £80 to £150
Display board replacedTypically £150 to £350
Main PCB replacedTypically £250 to £600
Electrician to trace a tripping circuitTypically £60 to £150

PCB costs vary the most. A board for a common Ideal or Baxi combi sits towards the lower end, while boards for premium brands or older discontinued models cost more, and some boards must be configured to the exact boiler model on site. London labour rates, out-of-hours visits and difficult access also push prices up. If the boiler is more than about 10 to 15 years old and needs a new PCB, it is worth getting a replacement boiler quote as well. Keeping the boiler serviced, as explained in our boiler service cost guide, lets an engineer spot scorched connections and small leaks before they take out the electrics.

Frequently asked questions

Why is my boiler display blank?

Most often the boiler has lost power at the fused spur, the spur fuse has blown or a breaker has tripped. Some boilers also dim the screen in standby. If power is reaching the boiler and it is still blank, call a Gas Safe registered engineer.

What fuse does a boiler spur take?

Commonly a 3 amp fuse, but always use the rating printed on the old fuse or in the installation manual.

Can I reset a boiler with no power?

No. The reset button only works when the boiler has power. Restore the supply first, then reset it as described in the manual if a fault code appears.

Why does the boiler fuse keep blowing?

A fuse that blows again straight away means a fault, such as a failing pump, fan, PCB or water in the wiring. Stop replacing it and call a Gas Safe registered engineer.

Should I call an electrician or a gas engineer?

If the consumer unit keeps tripping with the boiler switched off at the spur, call an electrician. If the tripping stops when the boiler is isolated, or the boiler has power but will not start, call a Gas Safe registered engineer.

Fault code meanings can differ between boiler models and software versions. Always check the user manual for your exact model. This page is general information, not a substitute for an inspection by a Gas Safe registered engineer. Read our disclaimer.