Boiler Not Firing Up: Gas, Ignition and Oil Supply Checks

Quick answer

A boiler that will not fire up is usually not getting fuel to the burner or not detecting a flame once it lights. Check that other gas appliances work, that a prepayment meter has credit, that the condensate pipe is not frozen and that the pressure is at least 1 bar. If it then shows an ignition lockout code, reset it once and call a Gas Safe registered engineer if it fails again.

On this page
  1. Why is my boiler not firing up?
  2. What is an ignition lockout?
  3. Gas supply checks you can do
  4. Can a frozen condensate pipe stop a boiler firing?
  5. Other reasons a gas boiler will not ignite
  6. Worcester boiler not firing up
  7. Oil boiler not firing up
  8. When to call an engineer

Why is my boiler not firing up?

A boiler fails to fire up for one of three reasons: it is not being asked to light, it cannot get fuel or air to the burner, or it lights but cannot confirm the flame. The first is a controls problem. The second and third are what this guide covers.

When the thermostat or a hot tap calls for heat, a modern gas boiler runs through a fixed sequence. The fan starts and the boiler checks the air flow. The gas valve opens and the ignition electrode sparks. A flame sensing electrode then has a few seconds to detect the flame. If it does, the boiler runs. If it does not, the gas valve shuts and the boiler tries again. After a set number of failed attempts, it stops and locks out.

If you can hear the spark ticking but nothing lights, our guide to a boiler clicking but not lighting covers that symptom in detail. If the boiler shows no signs of trying to start at all, and the display is lit, check the thermostat, timer and summer mode first, because the boiler may simply not be receiving a call for heat.

What is an ignition lockout?

An ignition lockout is a safety shutdown that happens when the boiler has tried to light and failed to detect a flame. The gas valve closes, a code appears and the boiler stays off until someone presses reset. It will not clear on its own, even if the cause goes away, because the boiler wants a person to check before it releases gas again.

Every manufacturer has its own code for this. The table lists the common ones, with our full pages on each.

BrandCodeWhat the manual calls it
Vaillant ecoTECF28Ignition unsuccessful at start-up (F29 is flame loss while running)
Ideal LogicL2Ignition lockout (F2 is flame loss)
Baxi and PottertonE133Gas supply interruption or ignition failure
Worcester Bosch GreenstarEA 227No flame detected (EA 229 is flame loss)
Glow-wormF28Ignition failure, similar to Vaillant
VokeraA01Ignition failure
Viessmann VitodensF4No flame signal

Code names and meanings vary between model ranges and software versions, so always check the user manual or the label inside the front flap for your exact boiler.

Gas supply checks you can do

Most ignition lockouts that homeowners can fix come down to the gas supply. Work through these before you reset:

  1. Try another gas appliance. If the gas hob or fire will not light either, the problem is the supply to the house, not the boiler.
  2. Check a prepayment meter. Make sure there is credit and that emergency credit has not run out. After a top-up, some meters need a button pressing before the gas flows again; your supplier's meter instructions explain this. British Gas advises that when a meter runs out of credit and switches off, the boiler may need a reset using the manufacturer's instructions.
  3. Check the meter valve. The emergency control valve handle next to the gas meter should be in line with the pipe. If it is across the pipe, the gas is off.
  4. Check the boiler's own gas valve. Many boilers have a gas isolation valve on the pipe underneath. It should also be in line with the pipe.
  5. Think about recent work. A new meter, a new hob or work on the gas pipes can leave air in the supply. The boiler may fail to light the first few times afterwards. Leave purging the pipework to the Gas Safe registered engineer who did the work.

Never try to adjust the gas valve, loosen gas fittings or remove the boiler casing. If you smell gas, turn off the supply at the meter if you can, open windows, leave the property and call the National Gas Emergency Service on 0800 111 999.

Can a frozen condensate pipe stop a boiler firing?

Yes. A frozen condensate pipe is one of the most common reasons a condensing boiler will not fire in cold weather. When the pipe freezes, the acidic water that the boiler produces cannot drain away. It backs up inside, and the boiler either detects the blockage directly or struggles to keep a stable flame. On many models this shows as an ignition or flame code rather than a specific condensate warning, which is why an Ideal L2 or a Vaillant F28 on a freezing morning often turns out to be ice in the pipe.

Signs include gurgling from the boiler, a pipe outside that is frozen solid and a lockout during a cold snap. Thaw the outside section with warm water from a kettle that has cooled for a while, or a hot water bottle, then reset the boiler once. Our guide to a frozen condensate pipe gives the full steps and explains how to stop it happening again.

Other reasons a gas boiler will not ignite

If gas is reaching the boiler and the condensate is clear, the cause is inside the boiler. These all need a Gas Safe registered engineer:

  • Worn or dirty ignition electrode. The spark weakens or jumps to the wrong place. This is a common failure on boilers that have missed services.
  • Faulty flame sensing electrode. The boiler lights but cannot detect the flame, so it shuts off within seconds.
  • Gas valve fault. The valve does not open, or opens but does not deliver the right pressure.
  • Fan or air pressure fault. The boiler will not try to light unless it proves enough air is moving through the flue.
  • Blocked flue or air intake. Birds' nests, debris or a damaged flue can stop the boiler lighting safely.
  • Low gas pressure at the boiler. The engineer measures this at the gas valve. It can be caused by an undersized gas pipe or a problem at the meter.
  • PCB fault. The control board runs the ignition sequence, and a fault there can stop it starting.

Low system water pressure can also stop a boiler firing, but most boilers show a separate low pressure code for that rather than an ignition code. If the gauge reads under 1 bar with the system cold, top it up before resetting.

Worcester boiler not firing up

A Worcester Bosch Greenstar that will not fire up usually shows EA 227 on the display, meaning the boiler tried to light and did not detect a flame. The checks are the same as for any gas boiler: gas to the hob, prepayment credit, the meter valve and, in winter, the condensate pipe.

Once you have checked those, reset the boiler once. On most Greenstar models the reset button is on the front control panel, but the exact method varies by model; our guide to a Worcester boiler reset covers each range. If EA 227 returns after 2 or 3 resets, the engineer will usually look first at the ignition and flame sensing electrodes, then the gas valve and the condensate siphon.

Oil boiler not firing up

An oil boiler that will not fire up is most often short of fuel or has a blockage between the tank and the burner. Oil boilers are not covered by Gas Safe, and anything beyond the checks below is a job for an OFTEC-registered technician. Our main oil boiler guide explains how the burner and fuel supply work.

CheckWhat to look forWho deals with it
Oil level in the tankSight gauge, remote monitor or dipstick shows very low or emptyYou: order oil
Recent deliveryBoiler failed soon after a delivery to a near-empty tankYou can wait for sediment to settle; technician if it persists
Oil supply valveValve at the tank or on the supply line turned offYou can check it is open
Burner lockout lightRed light or button lit on the burnerYou: one reset as the manual describes
Fire valve trippedSupply shut off at the fire valveOFTEC technician
Blocked filter or nozzle, air in the lineLights briefly then fails, or never lightsOFTEC technician
Dirty photocell or worn electrodesLocks out repeatedlyOFTEC technician

If the tank ran dry, air and sludge from the bottom of the tank may have entered the fuel line. The burner will then need bleeding and the filter changing, which is technician work. On an oil burner, press the lockout reset once and follow any reset limit in your boiler's user instructions. Do not keep pressing it: each failed attempt sprays oil into a chamber that has not lit, and that unburnt oil then has to be dealt with by a technician.

When to call an engineer

Call a Gas Safe registered engineer if the boiler locks out again after 2 or 3 resets, if other gas appliances work but the boiler will not light, or if you see soot, scorch marks or a yellow flame. For oil, call an OFTEC-registered technician. For LPG, use a Gas Safe engineer with LPG on their ID card.

Tell the engineer the code, what you have checked and whether the problem started after a cold night, a meter change or a fuel delivery. Typical UK prices for the usual parts are below; they vary with brand, access and region.

JobTypical UK cost
Diagnostic call-outTypically £60 to £120
Ignition or flame sensing electrodeTypically £100 to £200
Fan replacementTypically £200 to £400
Gas valve replacementTypically £250 to £450

Frequently asked questions

Why is my boiler not firing up?

Usually because gas or oil is not reaching the burner, or the boiler cannot detect the flame once it lights. Check other gas appliances, prepayment credit, the meter valve and the condensate pipe in cold weather. If it still locks out, the ignition electrode, flame sensor or gas valve may have failed.

What is an ignition lockout?

It is a safety shutdown after the boiler has tried to light and failed to detect a flame. The gas valve closes and the boiler shows a code, such as Vaillant F28, Ideal L2, Baxi E133 or Worcester EA 227. It stays off until you press reset, and repeated lockouts need an engineer.

Can a frozen condensate pipe stop a boiler firing?

Yes. When the condensate pipe freezes, water backs up inside the boiler and it locks out, often with an ignition or flame code rather than a condensate warning. Thaw the outside section with warm, not boiling, water and reset the boiler once.

Why is my oil boiler not firing up?

The most common reasons are an empty or nearly empty tank, sludge drawn into the line after a delivery, a closed supply valve or a burner lockout. Check the tank level and press the burner reset once. If it will not light, call an OFTEC-registered technician to check the filter, nozzle and fire valve.

Can low gas pressure stop a boiler firing?

Yes. If too little gas reaches the burner, the flame may not light or may not be stable enough for the boiler to detect, so it locks out. Only a Gas Safe registered engineer can test the gas pressure at the boiler. An undersized pipe or a meter problem are common causes.

Sources

How the prices on this page were put together: typical UK prices for the parts and labour involved, shown as ranges rather than quotes. In October 2026 we compared them with the published UK price guides from Checkatrade, MyBuilder, MyJobQuote and Fantastic Services. Prices vary by area, boiler model and engineer, so always ask for a written quote.

Fault code meanings can differ between boiler models and software versions. Always check the user manual for your exact model. This page is general information, not a substitute for an inspection by a Gas Safe registered engineer. Read our disclaimer.