Combi Boiler Pipes and Valves: Which Should Be Open or Closed?

Quick answer

Under a combi boiler, the isolation valves on the gas, heating and water pipes should normally be open, and the filling loop valves should be closed except while you top up the pressure. A valve is open when its lever or screw slot runs in line with the pipe, and closed when it sits across it.

On this page
  1. The pipes under a combi boiler, one by one
  2. How to tell if a valve is open or closed
  3. Which way each valve should be left
  4. The filling loop: built in or braided hose
  5. What happens if a valve is in the wrong position
  6. The discharge pipe and losing pressure
  7. Combi, system and regular boilers, and brand differences

The row of pipes under a combi looks confusing, but each one has a single job. Once you know what they do and how to read a valve, you can check the positions in a minute. You only ever need to operate two things yourself: the filling loop, and a look at the gas valve to confirm it is open.

The pipes under a combi boiler, one by one

Most combis have five copper pipes in a row across the bottom, plus a plastic condensate pipe and a smaller copper discharge pipe. A common layout from left to right is heating flow, hot water out, gas, cold mains in and heating return, but the order varies between brands and models. The diagram in your installation manual shows the layout for your boiler.

PipeWhat it doesValve on it
Gas inletBrings gas from the meter to the boilerGas isolation valve, usually with a yellow or black lever
Heating flowSends hot water out to the radiatorsIsolation valve
Heating returnBrings cooler water back from the radiatorsIsolation valve, sometimes with a filter nearby
Cold mains inSupplies cold water for the boiler to heat for your tapsIsolation valve
Hot water outCarries hot water to your taps and showerUsually none, or an isolation valve
CondensatePlastic pipe carrying acidic waste water to a drainNone
Pressure relief dischargeCopper pipe that dumps water outside if pressure gets too highNone

The filling loop is the link between the cold mains pipe and the heating circuit. It lets you add water when the pressure drops.

How to tell if a valve is open or closed

Valves under boilers turn a quarter of a turn between open and closed, so the rule is simple:

  • Lever handle: in line with the pipe means open. Across the pipe, at a right angle, means closed.
  • Screw slot: many water isolation valves have a slot for a flat screwdriver instead of a lever. Slot running along the pipe means open, slot across the pipe means closed.
  • Filling loop taps: these may be small levers, knobs or slots, and follow the same rule.

Some valves are hidden behind a plastic cover or pipe shroud, which simply unclips. Do not remove the boiler's front casing to look.

Which way each valve should be left

ValveNormal positionCan you touch it?
Gas isolation valveOpen (in line)Look only
Heating flow and return valvesOpenLeave for an engineer
Cold mains valveOpenLeave for an engineer
Filling loop valvesClosedYes, only to top up pressure

Engineers close the heating and water valves to work on the boiler without draining the whole house, and they should open them again when they finish. If one looks closed and you have no hot water or heating since a recent visit, ask the engineer to come back rather than turning it yourself.

If the gas valve lever sits across the pipe and you did not close it, do not simply open it: someone may have shut it for a safety reason. Call a Gas Safe registered engineer. If you smell gas, do not touch any boiler valve. Turn off the emergency control valve at the gas meter if it is safe to do so, open windows and call the National Gas Emergency Service on 0800 111 999.

The filling loop: built in or braided hose

There are two main types. An external filling loop is a silver braided hose with a tap at each end, joining the cold mains to the heating return under the boiler. An integral filling loop is built into the boiler and is worked with a lever, a knob or a removable key, depending on the brand. Our boiler filling loop guide covers both in detail.

To top up, open the filling loop valves slowly, watch the gauge rise to the level your manual gives (usually 1 to 1.5 bar cold), then close both valves fully. Many external hoses are meant to be disconnected after use.

A stiff filling loop valve is common because it is rarely used. Turn it gently by hand or with the correct key. Do not force it with pliers or a long lever, because a snapped valve can flood the floor. A seized loop is a simple job for a heating engineer or plumber.

What happens if a valve is in the wrong position

  • Gas valve closed: the boiler tries to light, fails and shows an ignition lockout code.
  • Heating valve closed: no heat reaches the radiators, and the boiler may overheat or show a circulation fault.
  • Cold mains valve closed: the boiler has no water to heat, so the hot taps run dry or barely trickle while the cold taps work normally.
  • Filling loop left open: mains water keeps pushing into the heating system, the pressure climbs past 3 bar and the boiler dumps water through the discharge pipe outside.

The discharge pipe and losing pressure

The small copper pipe running outside is there so the boiler can release water safely if the pressure gets too high. A filling loop left open, or one that lets water through when closed, is a common reason for it dripping. Our guide to the boiler pressure relief valve explains why it drips and what an engineer will check. Replacing that valve is an engineer job.

Pressure going the other way, falling over days or weeks, usually means a small leak on a radiator or pipe joint, water lost through that discharge pipe, or an expansion vessel that has lost its air charge. Recently bled radiators also drop the pressure. See our guide to a boiler losing pressure for how to narrow it down.

Combi, system and regular boilers, and brand differences

A system boiler has no cold mains in or hot water out, because it heats a cylinder instead. You will find heating flow and return pipes, a gas pipe, a filling loop, a discharge pipe and a condensate pipe, plus motorised valves nearby that direct water to the radiators or the cylinder. A regular (heat only) boiler fed from a tank in the loft often has no filling loop at all, since the tank tops the system up. Valve styles, colours and pipe order vary between Worcester Bosch, Vaillant, Ideal, Baxi and other makers, but open in line and closed across holds for all of them.

Anything beyond the filling loop and a look at the gas valve, including gas pressure checks, replacing any valve and working on the heating isolation valves, is a job for a Gas Safe registered engineer. For more on how combis work, see our combi boiler guide.

Frequently asked questions

Should the valves under a combi boiler be open or closed?

The gas, heating and cold mains isolation valves should normally be open, with their levers or slots in line with the pipe. The filling loop valves are the exception and should stay closed unless you are topping up the pressure.

Should the filling loop valves on my combi be left open?

No. Open them only while topping up, then close both fully. A loop left open lets mains water push the pressure too high, and the boiler then releases water through its discharge pipe.

How can I tell if the gas valve under my boiler is open?

Look at the lever on the gas pipe. If it runs in line with the pipe, it is open; if it sits across the pipe, it is closed. If it is closed and you do not know why, call a Gas Safe registered engineer rather than opening it.

Are the valves on an Ideal combi boiler set the same way?

Yes. The pipe order and valve styles differ between brands, but on an Ideal combi, as on any other, the isolation valves are left open and the filling loop is kept closed.

Can I turn the isolation valves under my combi myself?

The only valves an owner needs to use are the filling loop valves. Leave the heating and water isolation valves to an engineer, and only look at the gas valve to check it is open.

Fault code meanings can differ between boiler models and software versions. Always check the user manual for your exact model. This page is general information, not a substitute for an inspection by a Gas Safe registered engineer. Read our disclaimer.