Ideal Boiler L6 Fault Code: False Flame Lockout Explained

Quick answer

L6 on an Ideal boiler is a false flame lockout. The boiler has detected what looks like a flame at a moment when there should not be one, so it has shut down and locked out for safety. You can reset it once or twice, but if L6 returns, a Gas Safe registered engineer needs to check the flame sensing electrode, gas valve and control board.

On this page
  1. What the L6 code means
  2. Common causes of L6
  3. Safe checks you can do yourself
  4. When to call a Gas Safe engineer
  5. Typical repair costs in the UK
  6. How to stop L6 coming back

What the L6 code means

Your boiler uses a flame sensing electrode to confirm that the burner is lit. When the gas valve opens and the spark fires, the electrode picks up a small electrical signal from the flame. When the burner goes out, that signal should disappear. The control board watches this signal all the time, and it expects the answer to match what it has told the boiler to do.

A false flame is when the board sees a flame signal at the wrong time, for example before the boiler has tried to light, or after the gas valve has been told to close. That does not make sense, so the boiler cannot trust its own flame detection. It locks out with L6 and waits for a manual reset. Ideal lists L6 as a false flame lockout in the fault finding section of its Logic, Logic Combi2 and Logic Max installation manuals.

Because L is a lockout code, L6 will not clear by itself. The boiler stays off until it is reset.

Common causes of L6

A faulty or contaminated flame sensing electrode

The electrode sits in the combustion chamber and slowly builds up deposits. A worn, cracked or badly positioned electrode can give an unreliable signal, including one that suggests a flame is present when it is not.

Moisture or condensation in the combustion area

Condensing boilers produce a lot of water. Damp around the electrode or its lead can create a stray electrical path that the board reads as a flame signal.

A gas valve that is not closing fully

If the gas valve lets a small amount of gas through when it should be shut, a small flame can keep burning after the boiler has turned off. This is the most serious possible cause, and it is one reason L6 should always be looked at by an engineer if it repeats.

Wiring or control board faults

A damaged electrode lead, a poor earth or a fault in the flame detection circuit on the board can all produce a false reading.

CauseTypical signWho fixes it
Worn or dirty flame sensing electrodeL6 now and then, often with a history of ignition troubleGas Safe engineer
Moisture near the electrodeFault in damp or very cold weatherGas Safe engineer
Gas valve not closing fullyL6 soon after the burner shuts downGas Safe engineer
Wiring, earth or PCB faultElectrode and valve test fineGas Safe engineer

Safe checks you can do yourself

A false flame fault involves gas and flame detection parts, so your checks are limited. These steps are safe.

  1. Check for any smell of gas around the boiler or meter. If you smell gas, do not reset the boiler. Follow the warning below.
  2. Check the fused spur is on and that there have been no recent electrical problems in the house.
  3. Press reset once, following the method in your manual. On many Ideal models you hold the reset button for a few seconds.
  4. Watch the boiler for a few minutes. Note whether L6 returns during start-up, while the burner is running or just after it shuts down.
  5. If it returns, reset no more than two or three times in total. After that, switch the heating off at the controls and call an engineer.

If you smell gas, do not press reset or operate electrical switches. Turn off the gas at the meter if it is safe to do so, open doors and windows, leave the property and call the National Gas Emergency Service on 0800 111 999. Never remove the casing or touch the electrode, gas valve or PCB yourself.

When to call a Gas Safe engineer

Call a Gas Safe registered engineer if L6 comes back after a reset, or if it appears more than once in a short period. The engineer will inspect and test the flame sensing electrode and its lead, check the gas valve is closing properly, and test the earth and flame detection circuit on the board. They will also run a combustion check.

When you book, tell them the exact code and when it appeared. A false flame shortly after the burner shuts down points towards the gas valve, while a fault on start-up points towards the electrode or board. That detail helps them bring the right parts.

Too many resets in a short time can also lead to an LC lockout, which is another reason not to keep pressing reset. If your boiler is still under its manufacturer's warranty, contact Ideal or your installer first, as electrode and valve faults may be covered.

Typical repair costs in the UK

These are typical ranges including parts and labour. Prices vary by model, area and engineer.

JobTypical UK cost
Engineer call-out and diagnosisTypically £80 to £150
Ignition or flame sensing electrode replacementTypically £100 to £180
Ignition lead replacementTypically £80 to £150
Gas valve replacementTypically £250 to £450
Replacement PCBTypically £300 to £550

How to stop L6 coming back

The flame sensing electrode wears slowly, and a yearly service is the best time to inspect and replace it before it causes trouble. Our boiler service cost guide explains what a service includes. Keep the condensate pipe clear in winter, because water backing up into the boiler can cause a range of faults. Our frozen condensate pipe guide explains how to thaw it safely. If your boiler struggles to light rather than showing a false flame, see our page on the Ideal L2 ignition lockout.

Frequently asked questions

What does L6 mean on an Ideal boiler?

L6 is a false flame lockout. The boiler detected a flame signal at a time when there should have been no flame, so it locked out for safety.

Is an Ideal L6 fault dangerous?

The lockout itself keeps you safe, but one possible cause is a gas valve that is not closing fully. That is why a repeating L6 needs a Gas Safe registered engineer. If you smell gas, call 0800 111 999.

How do I reset L6 on an Ideal boiler?

Press the reset button as your manual describes, often holding it for a few seconds. If L6 comes back after two or three attempts, stop and call an engineer.

How much does it cost to fix Ideal L6?

If the flame sensing electrode is the cause, expect typically £100 to £180 fitted. A gas valve is typically £250 to £450 and a PCB typically £300 to £550.

Other Ideal fault codes

Full list →

Fault code meanings can differ between boiler models and software versions. Always check the user manual for your exact model. This page is general information, not a substitute for an inspection by a Gas Safe registered engineer. Read our disclaimer.