Ideal Boiler LC Fault Code: Too Many Resets Explained

Quick answer

LC on an Ideal boiler means it has been reset or restarted five times within 15 minutes, so it has locked out to stop further attempts. Ideal's advice is to turn the power off and on again at the fused spur. The real question is why it needed so many resets, so look up the original code and call a Gas Safe registered engineer if it returns.

On this page
  1. What the LC code means
  2. Common causes of LC
  3. Safe checks you can do yourself
  4. When to call a Gas Safe engineer
  5. Typical repair costs in the UK
  6. How to stop LC coming back

What the LC code means

Most Ideal lockout codes, such as L2 or L6, are cleared by pressing reset. That is fine once or twice, but repeatedly resetting a boiler with a real fault can be unsafe. For example, pressing reset over and over on a boiler that keeps failing to light means the burner keeps trying to ignite gas without a proper flame.

To prevent that, Ideal boilers count restarts. On the Logic Combi2 and Logic Max ranges, Ideal's manuals list LC as five restarts within 15 minutes, with the instruction to turn the power off and on. Once the limit is reached, the reset button stops working and the boiler shows LC instead.

LC is not a fault in itself. It is a sign that the boiler has been locking out repeatedly with another code, and that code is the one that needs fixing.

Common causes of LC

A repeating ignition lockout

The most common story is an L2 ignition lockout that keeps coming back. Someone presses reset, the boiler tries to light and fails, and after a few cycles LC appears. The underlying cause is often the gas supply, a prepayment meter out of credit or a frozen condensate pipe.

Repeated flame loss or false flame

An F2 flame loss fault or an L6 false flame lockout that keeps recurring can also lead to LC if the boiler is reset each time.

Overheat or circulation lockouts

An L1 lockout caused by poor circulation can repeat quickly if the pump or system has a problem, pushing the restart count up.

Power interruptions

Less often, repeated power cuts or a loose supply connection can make the boiler restart several times in a short spell.

Underlying causeTypical signWho fixes it
Gas supply or prepayment creditHob will not light eitherYou, by restoring the supply
Frozen condensate pipeFreezing weather, gurgling from the boilerYou, by thawing the pipe
Ignition or flame sensing faultL2, F2 or L6 before LC appearedGas Safe engineer
Circulation or pump problemL1 before LC appearedGas Safe engineer
Power supply problemLights flickering or trippingElectrician or Gas Safe engineer

Safe checks you can do yourself

  1. Try to remember which code the boiler showed before LC. If you are not sure, the engineer can often read the fault history from the boiler.
  2. Check your other gas appliances. If the hob will not light, the problem is the gas supply rather than the boiler.
  3. If you have a prepayment meter, check the credit and top up if needed.
  4. Check the gas isolation valve under the boiler. The handle should be in line with the pipe, which means it is open.
  5. In freezing weather, check the condensate pipe outside for ice and thaw it with warm (not boiling) water. Our frozen condensate pipe guide explains how.
  6. Turn the boiler off at the fused spur, wait a minute and turn it back on. This clears LC on the models that use it.
  7. If the original code comes back, reset it no more than once or twice more. After that, leave the boiler off and call an engineer.

If you smell gas, do not reset the boiler or turn it off and on. Turn off the gas at the meter if it is safe to do so, open doors and windows, leave the property and call the National Gas Emergency Service on 0800 111 999.

When to call a Gas Safe engineer

If you have restored the gas supply or thawed the condensate pipe and the boiler now runs normally, you may not need anyone. But if the original lockout keeps returning after a power restart, stop resetting and call a Gas Safe registered engineer. Seeing LC means the boiler has already had several failed attempts, and more resets are very unlikely to help.

When you book, give the engineer the code that appeared before LC if you know it. That tells them far more than LC on its own. It also helps to say how many times the boiler was reset, whether your other gas appliances were working and whether the weather was freezing at the time. With that information they can usually narrow the problem down to the gas supply, the ignition and flame sensing parts, or the water circulation side of the boiler before they arrive.

Call sooner if LC appears again within a day or two of clearing it. A boiler that keeps hitting the restart limit has a fault that is not going away, and running it on repeated resets only adds wear to parts such as the electrode and fan.

Typical repair costs in the UK

Clearing LC itself costs nothing. What you pay depends entirely on the underlying fault. These typical ranges include parts and labour.

JobTypical UK cost
Engineer call-out and diagnosisTypically £80 to £150
Ignition or flame sensing electrode replacementTypically £100 to £180
Rerouting or insulating the condensate pipeTypically £100 to £250
Replacement pump, fittedTypically £250 to £450
Gas valve replacementTypically £250 to £450

How to stop LC coming back

The simplest rule is to stop after two or three resets and find out why the boiler keeps locking out. Keep prepayment credit topped up in winter, and ask an engineer about insulating an exposed condensate pipe. A yearly service catches worn electrodes and circulation problems early. Our boiler service cost guide explains what it covers. It is also worth reading up on the original code, so you know which checks are safe to make yourself next time.

Frequently asked questions

What does LC mean on an Ideal boiler?

LC means the boiler has been reset or restarted five times within 15 minutes. It locks out to stop further attempts until the power is turned off and on.

How do I clear LC on an Ideal boiler?

Turn the boiler off at the fused spur, wait a minute and turn it back on. Then deal with the original fault that caused the repeated resets.

Why does my Ideal boiler keep going to LC?

Because another fault keeps returning and the boiler keeps being reset. Common causes are ignition lockouts from a gas supply problem or frozen condensate pipe. If it persists, call a Gas Safe registered engineer.

Is LC a serious fault?

LC itself is a safety limit rather than a fault. How serious it is depends on the code behind it, which is why an engineer should find the underlying cause if it keeps happening.

Other Ideal fault codes

Full list →

Fault code meanings can differ between boiler models and software versions. Always check the user manual for your exact model. This page is general information, not a substitute for an inspection by a Gas Safe registered engineer. Read our disclaimer.