Potterton E110 Fault Code: Boiler Overheat Explained

Quick answer

E110 on a Potterton boiler means the safety thermostat has operated because the boiler got too hot, so it has shut down. It is nearly always linked to poor circulation, such as low pressure, trapped air, sludge or a pump that is not moving water. Let the boiler cool, check the pressure and reset it, and call a Gas Safe registered engineer if E110 comes back.

On this page
  1. What the E110 code means
  2. Common causes of E110
  3. Safe checks you can do yourself
  4. When to call a Gas Safe engineer
  5. Typical repair costs in the UK
  6. How to stop E110 coming back

What the E110 code means

The Promax, Titanium, Gold and Assure manuals all list E110 as "safety thermostat operated". The safety thermostat is an overheat cut-out that works separately from the boiler's normal temperature control. If the water in the boiler passes a set limit, it switches the burner off and the boiler locks out.

The older Promax manual groups E110 with E130 (flue sensor operated) as its overheat faults, and gives them a slightly different reset from other codes, covered below. Because Potterton is part of the Baxi group, the fault works in much the same way as Baxi E110.

On Promax, Titanium and Gold boilers the code shows as "E1" alternating with "10". On an Assure it shows as 110 with a symbol beside it.

Why the boiler overheats

The burner puts heat into the water, and the circulating water carries it away to the radiators or the hot water. If the water slows down or stops, heat builds up in the heat exchanger within seconds. That is why nearly every E110 investigation starts with circulation. The Gold Combi HE manual, for example, labels the related code E125 as a "pump fault", which shows how closely the two are linked.

Common causes of E110

CauseTypical signWho fixes it
Low system pressureGauge below 1 bar when coldYou, via the filling loop
Air in radiatorsCold at the top, gurglingYou, by bleeding radiators
Pump sticking or wornHumming, no heat reaching radiatorsGas Safe engineer
Sludge or blocked heat exchangerCold spots, kettling noises from the boilerGas Safe engineer
Diverter valve sticking (combis)Overheats mainly on heating or on hot waterGas Safe engineer
Faulty safety thermostat or sensorCirculation fine but E110 repeatsGas Safe engineer

Circulation problems

Low pressure, air and a tired pump are the most common triggers. On a Promax or Titanium that has run for many years, the pump is a frequent suspect.

Sludge and scale

Magnetite sludge in the heating circuit restricts flow. A kettling or rumbling sound from the boiler is a common clue that deposits are building up in the heat exchanger.

Diverter valve on combis

On a combi, the diverter valve sends hot water either to the radiators or to the hot water side. If it sticks part way, flow can drop enough to cause overheating.

Faulty components

Occasionally the safety thermostat or a temperature sensor fails and trips when the water is not actually too hot.

Safe checks you can do yourself

  1. Switch the heating and hot water off at the controls and give the boiler 15 to 20 minutes to cool.
  2. Check the pressure gauge. If it is below 1 bar when cool, top up to 1 to 1.5 bar using the filling loop. Our guide on how to repressurise a boiler explains the steps.
  3. Bleed any radiators that are cold at the top, with the heating off, then check the pressure again.
  4. Make sure several radiators are turned on.
  5. Reset the boiler. On a Promax, Titanium or Gold, the manual says to turn the selector to the reset position and hold it for at least five seconds for E110. On an Assure, press Reset for about one second. Try no more than two or three times.

Do not remove the casing, try to free the pump or touch the safety thermostat. These parts sit inside the boiler next to live wiring and gas components, so only a Gas Safe registered engineer should work on them.

When to call a Gas Safe engineer

If E110 returns after two or three resets, or you hear humming, kettling or banging from the boiler, book a Gas Safe registered engineer. They will usually check the pump, vent trapped air, test the safety thermostat and sensors, check the diverter valve on a combi and look for sludge. Mention if a circulation fault such as E125 has also appeared, as this helps narrow things down.

Heating or hot water?

It is worth noting whether E110 appears when the radiators are running, when you run a hot tap, or both. On a combi, overheating only on hot water can point towards the diverter valve or a scaled plate heat exchanger, while overheating only on heating points more towards the radiator circuit, the pump or sludge. That simple observation can save the engineer time. Also mention how long the boiler runs before the code appears, whether it is seconds after lighting or after half an hour of normal use.

Typical repair costs in the UK

Typical ranges only. Prices vary with the model, the parts and your area.

JobTypical UK cost
Engineer call-out and diagnosisTypically £80 to £150
Safety thermostat replacementTypically £100 to £180
Pump replacementTypically £250 to £450 fitted
Diverter valve repair or replacementTypically £150 to £350
PowerflushTypically £400 to £700

On an older Promax or Titanium, ask for a combined quote if more than one part is worn, and an honest view on whether a repair is still worthwhile.

How to stop E110 coming back

Keep the cold pressure between 1 and 1.5 bar and check it monthly. Run the heating briefly once a month over the summer so the pump and diverter valve do not stick. A magnetic filter and inhibitor help keep sludge under control on older systems. Book a yearly service so an engineer can spot a tired pump early. Our boiler service cost guide explains what is included, and our Potterton fault codes page lists the other codes we cover.

Frequently asked questions

What does E110 mean on a Potterton boiler?

It means the safety thermostat has operated because the boiler overheated. Poor circulation from low pressure, air, sludge or the pump is the usual cause.

How do I reset E110 on a Potterton Promax?

Let the boiler cool and check the pressure, then turn the selector to the reset position and hold it for at least five seconds. Stop after two or three attempts.

Is Potterton E110 dangerous?

The lockout stops the boiler getting any hotter, so it is not dangerous while locked out. Repeated overheating does need an engineer, as it can damage the boiler over time.

Why does my Potterton keep showing E110?

If the pressure is correct and the radiators are bled, a sticking pump, sludge, a diverter valve problem or a faulty thermostat is likely. A Gas Safe registered engineer needs to test them.

Other Potterton fault codes

Full list →

Fault code meanings can differ between boiler models and software versions. Always check the user manual for your exact model. This page is general information, not a substitute for an inspection by a Gas Safe registered engineer. Read our disclaimer.