Potterton E133 Fault Code: Gas Supply or Flame Failure

Quick answer

E133 on a Potterton boiler means an interruption of the gas supply or a flame failure, so the boiler could not light or keep its flame and has locked out. The most common causes are no gas reaching the boiler, an empty prepayment meter or a frozen condensate pipe. Check your gas supply and the condensate pipe, then reset the boiler no more than two or three times.

On this page
  1. What the E133 code means
  2. Common causes of E133
  3. Safe checks you can do yourself
  4. When to call a Gas Safe engineer
  5. Typical repair costs in the UK
  6. How to stop E133 coming back

What the E133 code means

Potterton manuals for the Promax, Titanium, Gold and Assure ranges all describe E133 in the same words: "interruption of gas supply or flame failure". Potterton is part of the Baxi group and these boilers share a lot of their design with Baxi models, so the code works the same way as Baxi E133.

When the boiler needs heat, the fan starts, the gas valve opens and the electrode sparks. A flame sensor then checks the burner has lit. If no flame is detected after the permitted attempts, the gas is shut off and the boiler locks out with E133.

How E133 looks on your display

This depends on the range, and it catches a lot of people out:

  • Promax, Titanium and Gold: the display can only show two characters at once, so E133 appears as "E1" alternating with "33".
  • Assure: the display shows 133 with a symbol beside it. An R means you can try a reset. The Assure also has a related code, 135, for an interruption of the gas supply caused by an internal error.

Common causes of E133

No gas reaching the boiler

A prepayment meter out of credit, a gas isolation valve knocked closed or a supply problem in the street all stop the boiler lighting. Check other gas appliances first.

Frozen condensate pipe

In a hard frost the condensate pipe can freeze where it runs outside. Water backs up inside the boiler and it cannot light, so E133 is very common on cold mornings.

Ignition electrode

The electrode wears and can drift out of position. The boiler may click repeatedly without lighting.

Gas valve, fan, flue or control board

If gas is available and the pipe is clear, the fault is inside the boiler. The gas valve, fan, flue and control board all need testing by an engineer.

CauseTypical signWho fixes it
Prepayment meter out of creditHob will not light eitherYou, by topping up
Gas isolation valve closedHandle across the pipe under the boilerYou, by opening it
Frozen condensate pipeFreezing weather, gurgling from the boilerYou, by thawing it
Worn ignition electrodeClicking without lighting, fault more frequentGas Safe engineer
Gas valve or control boardGas supply fine, E133 every timeGas Safe engineer

Safe checks you can do yourself

  1. Try your hob or another gas appliance. If nothing lights, the problem is the supply, not the boiler.
  2. If you have a prepayment meter, check the credit and top up, then follow the meter's instructions to restore the supply.
  3. Check the gas isolation valve under the boiler is open, with the handle in line with the pipe.
  4. In freezing weather, find the condensate pipe outside and thaw it with warm (not boiling) water or a hot water bottle. Our frozen condensate pipe guide shows how.
  5. Check the fused spur is on and the thermostat and timer are calling for heat.
  6. Reset the boiler the right way for your model. On an Assure, press Reset for about one second, as holding it for more than two seconds will not reset it. On a Promax, Titanium or Gold, turn the selector to the reset position and hold for about five seconds. Try no more than two or three times.

If you smell gas, do not reset the boiler or use electrical switches. Turn off the gas at the meter if it is safe to do so, open doors and windows, leave the property and call the National Gas Emergency Service on 0800 111 999.

When to call a Gas Safe engineer

If gas is reaching your other appliances, the condensate pipe is clear and E133 keeps coming back, call a Gas Safe registered engineer. They will usually check the gas pressure at the boiler, the electrode and its gap, the gas valve, the fan and flue, and the condensate trap. On an Assure, an engineer can also read the stored fault history.

If your Potterton is still under warranty, contact Baxi customer support first, as it handles Potterton warranty repairs. Using another engineer could affect the cover.

Spotting a pattern

Before the engineer arrives, think about when E133 appears. A fault that only shows on frosty mornings points to the condensate pipe. One that appears after the prepayment meter has been topped up points to the supply. One that happens at random and is getting more frequent is more likely to be a worn electrode or a gas valve starting to fail. Passing on that pattern helps the engineer focus on the right part first, which usually means a shorter visit and a smaller bill.

Typical repair costs in the UK

Typical ranges only. Costs depend on the model, the part and your area.

JobTypical UK cost
Topping up credit or thawing the pipeFree
Engineer call-out and diagnosisTypically £80 to £150
Ignition electrode replacementTypically £100 to £180
Gas valve replacementTypically £250 to £450
Insulating or rerouting the condensate pipeTypically £100 to £250

How to stop E133 coming back

Keep prepayment credit topped up in winter, when gas use climbs quickly. If E133 mostly appears on frosty mornings, ask an engineer about insulating the condensate pipe or rerouting it indoors. The Assure manual notes this pipe must only be altered by a qualified professional. An annual service lets the engineer clean and check the electrode and condensate trap before they cause a lockout. See our boiler service cost guide for what is included. For other Potterton codes, see our Potterton fault codes page.

Frequently asked questions

What does E133 mean on a Potterton boiler?

It means an interruption of the gas supply or a flame failure. The boiler could not light or keep its flame, so it locked out for safety.

Why does my Potterton show E1 and 33?

On Promax, Titanium and Gold boilers the display alternates between "E1" and "33" to show E133, because it can only show two characters at a time.

How do I reset a Potterton boiler showing E133?

On an Assure, press Reset for about one second. On a Promax, Titanium or Gold, hold the selector in the reset position for about five seconds. Stop after two or three attempts.

Can a frozen condensate pipe cause Potterton E133?

Yes, it is one of the most common causes in cold weather. Thaw the pipe with warm (not boiling) water or a hot water bottle, then reset the boiler.

How much does it cost to fix Potterton E133?

Nothing if the cause is gas credit or a frozen pipe. An electrode is typically £100 to £180 and a gas valve typically £250 to £450, plus call-out.

Other Potterton fault codes

Full list →

Fault code meanings can differ between boiler models and software versions. Always check the user manual for your exact model. This page is general information, not a substitute for an inspection by a Gas Safe registered engineer. Read our disclaimer.