What E37 means
E37 tells you the boiler is not getting enough voltage from the mains to work properly, so it has stopped. In the error table of Alpha's E-Tec 28 and 33 installation and servicing instructions, code 37 is listed as "low supply voltage", with the explanation that the supply is insufficient to operate the boiler. Alpha's InTec2 26CE, 30CE and 35CE installation and servicing instructions carry the same entry. The manuals print the bare number, and the boiler shows it on the display as E37.
The boiler's control board needs a steady supply to run the fan, the pump and the ignition. When the voltage sags too far, the board stops rather than risk running those parts unreliably. That makes E37 different from most Alpha codes: the cause is usually outside the boiler, in the supply feeding it.
Which Alpha models use E37
The code is confirmed in the manuals for the E-Tec 28 and 33 and the InTec2 26CE, 30CE and 35CE. We could not find it in the part of the E-Tec Plus error table we were able to read, so if you have an E-Tec Plus, check your own manual before assuming E37 means the same thing. The InTec2 table also lists a separate electrical code, E59, for an incorrect mains frequency, which an engineer would treat as a related supply problem.
For the full list of codes from these manuals, see our Alpha boiler fault codes page.
What Alpha tells engineers to check
The manual's checks for code 37 are short, and both are about the electrical feed:
- The mains power supply. Is the voltage arriving at the boiler high enough and steady?
- Bad cable connections. A loose or poor connection between the supply and the boiler can cause the voltage to drop at the boiler even when the house supply is fine.
In practice that splits into three possibilities, and they show up differently.
| Where the problem is | Clues you may notice | Who sorts it |
|---|---|---|
| The supply to your street or home | Lights dimming or flickering, other appliances misbehaving, neighbours affected | Your electricity network operator |
| Your home's wiring to the boiler, including the fused spur | Only the boiler is affected, a spur that feels warm or looks scorched, a fault that comes and goes | A qualified electrician |
| The connections inside the boiler | Supply tested as normal at the spur but E37 continues | A Gas Safe registered engineer |
Safe checks before you call anyone
- Look at the fused spur near the boiler (the wall switch, often with a small fuse holder) and make sure it is switched on.
- Check whether other lights and sockets in the house are working normally. Dimming or flickering lights point to a supply problem rather than the boiler.
- Look at your consumer unit for a tripped switch. If one has tripped, you can switch it back on once. If it trips again, leave it off and call an electrician.
- Ask a neighbour whether they have had any power issues. Your network operator can tell you about faults in the area.
- Once the supply looks normal, press reset if the boiler does not restart by itself, and see whether E37 returns.
Do not open the fused spur, the boiler casing or any wiring to look for a loose connection. Anything at mains voltage is a job for a qualified electrician (for the house wiring) or a Gas Safe registered engineer (for the boiler). If the spur or any cable feels hot, smells of burning or shows scorch marks, switch off at the consumer unit and get it checked before using the boiler again.
If the display is completely blank rather than showing E37, our guide to a boiler with no power or a blank display covers that situation step by step.
When E37 points to a repair
If the house supply is normal and E37 keeps appearing, the likely culprit is a poor connection somewhere between the spur and the boiler's control board. An electrician can test the voltage at the spur and check the cable to the boiler. If that is fine, a Gas Safe registered engineer will check the connections inside the boiler. Keep a note of when the fault appears, for example only in the evening when demand is high, or when a particular appliance switches on, because that pattern helps narrow down the cause.
A boiler that keeps losing power can also look like a boiler that randomly switches itself off. Our guide on a boiler that keeps turning off explains how to tell the difference.
Typical repair costs in the UK
If the cause was a tripped switch or a brief supply dip, E37 costs nothing to clear. Where a repair is needed on the boiler side, these are the typical ranges. Electrician charges for house wiring vary too much for us to give a fair range.
| Job | Typical UK cost |
|---|---|
| Gas Safe engineer call-out and diagnosis | Typically £60 to £150 |
| Minor repair to boiler wiring or a connection | Typically £100 to £180 |
| Gas engineer hourly rate | Typically £50 to £80 (London and the South East £90 to £110) |
What to tell the engineer or electrician
Tell them the boiler model (E-Tec or InTec2, and its size), that the display shows E37, and how often it appears. Mention any flickering lights, tripped switches or recent electrical work in the house, such as a new consumer unit or extra sockets on the same circuit. If you have smart controls or a wireless thermostat, mention those too, because the engineer will want to know everything wired into the boiler.