What E01 means
An Alpha boiler shows E01 when it has tried to light and failed to see a flame. Alpha's E-Tec 28 and 33 installation and servicing instructions list code 01 as "ignition failure", explained as no flame detected during the ignition sequence. The E-Tec Plus 28 and 33 installation and servicing instructions list the same fault. The tables give the number as 01, and the display shows E01.
Each time the boiler gets a call for heat or hot water, it runs the fan, makes a spark and opens the gas valve. A sensing electrode then confirms there is a flame. If no flame is confirmed in the time allowed, the boiler shuts the gas off and locks out. That shutdown is a safety feature: the boiler will not keep releasing gas it cannot see burning.
Which Alpha boilers use E01
E01 is confirmed in the manuals for the E-Tec 28, E-Tec 33, E-Tec Plus 28 and E-Tec Plus 33. Alpha's InTec user instructions also tell owners to press the reset button for a lockout and to contact the installer or the Alpha helpline if it keeps happening. If your boiler is from another range, check the code against its own manual. Our Alpha fault codes page lists the other codes from the same tables.
The four causes Alpha lists
Alpha gives four areas for the engineer to investigate. Only the first is something you can check yourself.
1. Gas supply
No gas means no flame. A prepayment meter that has run out of credit, a supply problem in the street or an isolation valve that has been turned off will all produce E01. It is also the only cause you can rule out without opening the boiler, so start here.
2. Ignition or sensing electrode
The electrode makes the spark and senses the flame. If it is worn, dirty, badly positioned or cracked, the boiler may light but fail to detect it, or fail to light at all.
3. Ignition generator or lead
The generator produces the high-voltage spark and the lead carries it to the electrode. A failed generator or damaged lead means no spark. You may hear the fan run but no repeated clicking from the ignition.
4. Gas valve operation
If the gas valve does not open, or does not open properly, gas never reaches the burner even when the supply to the house is fine.
| Cause | Clue | Who checks it |
|---|---|---|
| Gas supply | Hob also not lighting, meter out of credit, valve under the boiler turned off | You first, then your supplier or the gas emergency line |
| Electrode | Clicking heard but lockout follows, or boiler lights briefly then stops | Gas Safe engineer |
| Generator or lead | Fan runs but no clicking at all | Gas Safe engineer |
| Gas valve | Gas fine elsewhere in the house, spark present, still no flame | Gas Safe engineer |
Checks you can make yourself
- Turn on a gas hob or another gas appliance. If that will not light either, the problem is your supply, not the boiler.
- If you have a prepayment meter, check it has credit and that any emergency credit has not run out.
- Look at the gas isolation valve on the pipe under the boiler. The handle should line up with the pipe. If it is across the pipe, it is closed.
- Once you are confident gas is available, press the reset button and give the boiler a few minutes to try again.
- If E01 returns, try once more at most, then stop and book an engineer.
Pressing reset over and over does not fix ignition faults. The E-Tec 28 and 33 manual lists a separate code, E08, for when the maximum number of resets is reached (five), which locks the boiler out until an engineer looks at it.
If you smell gas, do not press reset or operate electrical switches. Turn the gas off at the meter if it is safe to do so, open doors and windows and call the National Gas Emergency Service on 0800 111 999. Never remove the boiler casing or touch the electrode, ignition lead or gas valve.
For a wider look at ignition problems across all makes, see our guide on a boiler that will not fire up.
How E01 differs from E38 and E43
E01 means the boiler never established a flame. Alpha uses different codes when a flame is found and then lost: E38 for a lost flame signal, where the boiler tries to relight, and E43 for repeated loss of the flame signal during operation. Telling the engineer which code you saw, and whether the boiler lit at all, saves diagnosis time.
Typical repair costs in the UK
A supply problem costs nothing beyond topping up your meter. If a part is at fault, these are the typical ranges.
| Job | Typical UK cost |
|---|---|
| Engineer call-out and diagnosis | Typically £60 to £150 |
| Ignition electrode replacement | Typically £90 to £180 |
| Ignition lead or spark generator | Typically £100 to £200 |
| Gas valve replacement | Typically £180 to £350 |
What to tell the engineer
Give your boiler model and size, the code, how many times you reset it and whether it lit briefly or not at all. Say whether you heard clicking, whether other gas appliances work, and when the boiler was last serviced. If E08 has appeared after several resets, mention that too.