Smell gas? Turn off the gas at the meter, open windows, do not use switches and call the National Gas Emergency Service on 0800 111 999.Smell gas? Call 0800 111 999

Vokera A01 Fault Code: Ignition Failure Explained

Quick answer

A01 on a Vokera boiler is an ignition failure. The boiler tried to light, but no flame was sensed, so it shut off the gas and locked out. The most common causes are a gas supply problem (including a prepayment meter out of credit) and, in freezing weather, a frozen condensate pipe. Check those first, then reset no more than two or three times.

On this page
  1. What the A01 code means
  2. Common causes of A01
  3. Safe checks you can do yourself
  4. When to call a Gas Safe engineer
  5. Typical repair costs in the UK
  6. How to stop A01 coming back

What the A01 code means

When your boiler gets a call for heating or hot water, it runs a start-up sequence. The fan starts, the gas valve opens, and an ignition spark lights the gas at the burner. A flame sensing electrode then confirms that a flame is present. If the boiler does not sense a flame within its safety time, it closes the gas valve and locks out.

On most current Vokera models, including the Vision, Vision Plus, Evolve, Easi-Heat Plus and Unica, the user manual lists A01 as ignition failure, flame not sensed or internal fault. It is a final lockout, which means the boiler stays off until it is reset. The manual's action for A01 is to call an engineer, but there are some simple outside causes that are worth ruling out first, because they are common and cost nothing to fix.

A01 is a safety feature. The boiler is stopping unburnt gas from building up, which is exactly what it should do.

Common causes of A01

No gas reaching the boiler

If the gas supply to the house has been interrupted, or the isolation valve under the boiler has been turned off, the boiler has nothing to light. Low gas pressure can have the same result.

Prepayment meter out of credit

This is one of the most frequent causes. Once the credit and emergency credit run out, the gas stops. The boiler shows A01 the next time it tries to fire.

Frozen or blocked condensate pipe

Condensing boilers drain waste water through a plastic pipe that often runs outside. In a hard frost it can freeze, water backs up, and many boilers lock out on an ignition fault as a result. A gurgling sound from the boiler is a common clue.

Ignition or flame sensing electrode

The electrodes wear over time. A dirty, worn or badly positioned electrode can fail to spark properly or fail to sense a flame that is present.

Gas valve, fan or control board

Less commonly, the gas valve does not open, the control board does not send the right signals, or there is an internal fault that stops the boiler lighting. These need testing by an engineer.

CauseTypical signWho fixes it
Prepayment credit run outHob or gas fire will not light eitherYou, by topping up
Gas isolation valve closedHandle across the pipe rather than in lineYou, by opening it
Frozen condensate pipeFreezing weather, gurgling from the boilerYou, by thawing the pipe
Worn or dirty electrodeGas supply fine, fault keeps returningGas Safe engineer
Gas valve or PCB faultRepeated lockouts with a good gas supplyGas Safe engineer

Safe checks you can do yourself

  1. Check your other gas appliances. If the hob or gas fire will not light, the problem is the gas supply, not the boiler. Contact your gas supplier.
  2. If you have a prepayment meter, check the credit and top up. Some meters need a button pressing to restore the supply after a top-up.
  3. Check the gas isolation valve on the pipe under the boiler. The handle should be in line with the pipe, which means it is open.
  4. In freezing weather, find the condensate pipe where it leaves the house and look for ice. Thaw it with warm (not boiling) water or a hot water bottle. Our frozen condensate pipe guide shows how.
  5. Check the thermostat and timer are calling for heat, so the boiler is actually trying to fire.
  6. Reset the boiler using the method in your manual. On many models you press and hold the reset button for a few seconds, and on some you turn the selector dial to the reset position.
  7. Give it a few minutes to run through the start-up sequence. Stop after two or three attempts.

If you smell gas, do not reset the boiler or use electrical switches. Turn off the gas at the meter if it is safe to do so, open doors and windows, leave the property and call the National Gas Emergency Service on 0800 111 999.

When to call a Gas Safe engineer

If your gas supply is working, the condensate pipe is clear and A01 comes back after two or three resets, the cause is inside the boiler. Call a Gas Safe registered engineer. They will check the gas pressure at the boiler, inspect the electrodes and leads, test the gas valve and look at the flue and control board.

When you book, give the exact code, the model name from the front of the boiler, and say whether your other gas appliances work and whether the fault started in cold weather. That helps them bring the right parts. Never remove the casing or try to clean or adjust the electrode yourself.

Typical repair costs in the UK

If the fix was a gas top-up or a thawed pipe, there is no cost. If a part has failed, these ranges are typical, including parts and labour.

JobTypical UK cost
Engineer call-out and diagnosisTypically £80 to £150
Ignition or flame sensing electrode replacementTypically £100 to £180
Ignition lead replacementTypically £80 to £150
Gas valve replacementTypically £250 to £450
Rerouting or insulating the condensate pipeTypically £100 to £250

How to stop A01 coming back

Keep prepayment credit topped up, especially in winter when gas use climbs quickly. If your condensate pipe runs outside, ask an engineer whether it can be insulated, enlarged or rerouted, as this is often the simplest way to avoid winter lockouts. A yearly service lets the engineer check and replace worn electrodes before they fail. Our boiler service cost guide explains what a service includes. If your boiler shows a pressure fault instead, see our page on the Vokera A04 low pressure code, and the Vokera fault code hub covers the rest.

Frequently asked questions

What does A01 mean on a Vokera boiler?

A01 is an ignition failure. The boiler tried to light, but no flame was sensed, so it locked out for safety.

How do I reset a Vokera boiler showing A01?

Deal with any gas supply or condensate problem first, then reset as your manual describes, usually by holding the reset button or turning the selector dial to reset. Stop after two or three attempts.

Can a frozen condensate pipe cause A01?

Yes, it is a common winter cause. Thaw the pipe with warm (not boiling) water or a hot water bottle, then reset the boiler.

Is A01 dangerous?

The lockout is a safety feature that stops gas building up. It only becomes urgent if you smell gas, in which case call the National Gas Emergency Service on 0800 111 999.

How much does it cost to fix Vokera A01?

It costs nothing if the cause is gas credit or a frozen pipe. If a part has failed, an electrode is typically £100 to £180 fitted and a gas valve typically £250 to £450.

Other Vokera fault codes

Full list →

Fault code meanings can differ between boiler models and software versions. Always check the user manual for your exact model. This page is general information, not a substitute for an inspection by a Gas Safe registered engineer. Read our disclaimer.