Quick answer

A10 on a Vokera Easi-Heat i is a flame lockout: the boiler could not run with a stable flame, so it shut the gas off and locked out. Vokera's manual links it to an obstructed condensate drain or a blocked flue exhaust or air intake. Check your gas supply and, in a frost, the condensate pipe, then hold the reset key for more than two seconds, but call a Gas Safe registered engineer if it returns.

On this page
  1. What A10 means on a Vokera boiler
  2. The two causes in Vokera's fault table
  3. Safe checks before you reset
  4. How to reset A10 on an Easi-Heat i
  5. When to call a Gas Safe registered engineer
  6. Typical repair costs in the UK

What A10 means on a Vokera boiler

A10 is the flame lockout code on the Vokera Easi-Heat i 25C and 29C. The fault table in section 3 of Vokera's Easi-Heat i users and installation instructions (document 20195442, edition 3) lists it as "Flame lockout" and marks it as definitive, so the boiler stays off until it is reset by hand. In that table, A10 sits alongside two specific conditions: "Condensate drain obstructed" and "Flue gas exhaust/air suction obstructed".

A lockout of this kind is a safety shutdown. When the boiler cannot be sure that gas is burning properly, it closes the gas valve rather than let unburnt gas build up or let flue gases back into the room. The lockout is the boiler doing its job. Your task is to find out why it happened.

A10 replaces A01 on older Vokeras

Older Vokera models such as the Compact A and Unica i use A01 for ignition failure, and their manuals say to reset and, on the Unica i, to check the gas is on. The Easi-Heat i uses the newer two digit code family, so A10 is its equivalent lockout. If your boiler shows A01, use that page instead, because the reset method on those models is different.

The two causes in Vokera's fault table

Condensate drain obstructed

The Easi-Heat i is a condensing boiler, so it produces acidic water that drains through a plastic pipe to a drain. If that pipe freezes or blocks, water backs up inside the boiler and it cannot run safely. The installation section of the manual sets out how the pipe should be run: plastic pipe of at least 21.5 mm outside diameter, falling at least 45 mm per metre away from the boiler, and at least 32 mm with insulation where it runs outside or through unheated space. It also tells installers to make sure the user knows what a blocked or frozen condensate pipe will do. A thin, uninsulated pipe running along an outside wall is the usual winter culprit.

Flue gas exhaust or air intake obstructed

The boiler draws its combustion air in and pushes waste gases out through the flue. If either path is restricted, by a nest, debris, ice, damage or a terminal that has been boxed in, the burner cannot run cleanly and the boiler locks out. Checking and clearing the flue is strictly a job for a Gas Safe registered engineer.

What you noticeMost likely link to A10Who deals with it
Hard frost, gurgling from the boiler, ice on the outside pipeFrozen condensate drainYou, by thawing the pipe
Hob or gas fire will not light eitherNo gas reaching the houseYou, then your gas supplier
Visible nest, debris or damage at the flue terminalFlue exhaust or air intake obstructedGas Safe engineer
A10 returns in mild weather with gas workingInternal condensate trap, flue or another faultGas Safe engineer

Safe checks before you reset

  1. Try another gas appliance, such as the hob. If nothing lights, check your prepayment credit or contact your gas supplier.
  2. Check the gas isolation valve on the pipe under the boiler. The handle should line up with the pipe, which means it is open.
  3. In freezing weather, follow the condensate pipe outside and look for ice. Thaw it with warm (not boiling) water or a hot water bottle. Our frozen condensate pipe guide shows where to pour and what to avoid.
  4. From outside, look at the flue terminal. If you see a nest, debris or damage, do not touch it. Note it for the engineer.
  5. Check the programmer and thermostat are calling for heat.
  6. Reset the boiler (see below). Give it a few minutes to try to light.

If you smell gas, do not reset the boiler or use electrical switches. Turn the gas off at the meter if it is safe to do so, open doors and windows, leave the property and call the National Gas Emergency Service on 0800 111 999.

How to reset A10 on an Easi-Heat i

Section 2.13 of the manual says to press and hold the reset key for more than two seconds, and the display shows "A10 Res" while the reset is available. If the correct operating conditions have been restored, the boiler starts up again by itself. The manual notes that with a remote control fitted, up to five consecutive unlock attempts are allowed, but we suggest you stop after two or three. If those attempts do not work, the manual's instruction is to contact Vokera's Technical Assistance Centre.

When to call a Gas Safe registered engineer

Call an engineer if A10 returns after two or three resets, if the gas supply and condensate pipe are both fine, or if you saw anything wrong with the flue. The engineer will usually check the condensate trap and pipe inside and outside, inspect the flue and air intake, measure the gas pressure at the boiler and look at the ignition and flame detection parts. If the condensate pipe freezes every winter, ask about upsizing, insulating or rerouting it in line with the 32 mm guidance above. For more on flue problems, see our boiler flue guide.

When you book, give the code, the model (Easi-Heat i 25C or 29C, shown on the front), whether other gas appliances work and whether the fault began in cold weather.

Do not remove the casing, disconnect the condensate trap or try to clear the flue yourself. Anything inside the boiler or on the flue must be handled by a Gas Safe registered engineer.

Typical repair costs in the UK

JobTypical UK cost
Thawing a frozen condensate pipe yourselfFree
Engineer call-out and diagnosisTypically £60 to £150
Condensate pipe reroute or insulateTypically £80 to £200
Flue repair or adjustmentTypically £150 to £400
Minor repair (small part, sensor or wiring)Typically £100 to £180

Other Vokera codes are listed on our Vokera fault code hub.

Frequently asked questions

Can a frozen condensate pipe cause Vokera A10?

Yes. Vokera's Easi-Heat i fault table links A10 to an obstructed condensate drain. Thaw the pipe with warm (not boiling) water, then hold reset for more than two seconds.

What does A10 Res mean on a Vokera display?

It shows that the A10 flame lockout can be reset. Hold the reset key for more than two seconds, and the boiler restarts if the cause has cleared.

Is Vokera A10 the same as A01?

They do the same job on different boilers. A10 is the flame lockout on the Easi-Heat i, while older models such as the Compact A and Unica i show A01 for ignition failure.

How much does it cost to fix Vokera A10?

Nothing if thawing the condensate pipe fixes it. Rerouting or insulating the pipe is typically £80 to £200, and a flue repair typically £150 to £400.

Sources

The meaning of A10 on this page comes from these manufacturer documents:

Codes and their meanings can change between models and software versions, so the manual for your exact boiler always comes first. Documents with a link open on the manufacturer's own website.

How the prices on this page were put together: typical UK prices for the parts and labour involved, shown as ranges rather than quotes. In October 2026 we compared them with the published UK price guides from Checkatrade, MyBuilder, MyJobQuote and Fantastic Services. Prices vary by area, boiler model and engineer, so always ask for a written quote.

Other Vokera fault codes

Full list →

Fault code meanings can differ between boiler models and software versions. Always check the user manual for your exact model. This page is general information, not a substitute for an inspection by a Gas Safe registered engineer. Read our disclaimer.