Vokera A40 Error Code: Fill the System (Low Pressure)

Quick answer

A40 on a Vokera Easi-Heat i means "fill the system": the water pressure in the heating circuit has stayed too low and the boiler has locked out. Top up through the filling loop until the pressure reads 1 to 1.5 bar, then hold the reset key for more than two seconds. If the pressure drops again soon after, there is a leak or a faulty part to find.

On this page
  1. What A40 means on a Vokera boiler
  2. How A41 turns into A40
  3. How to top up an Easi-Heat i and clear A40
  4. Why the pressure dropped
  5. Why A40 matters more in winter
  6. When to call a Gas Safe registered engineer
  7. Typical repair costs in the UK

What A40 means on a Vokera boiler

A40 is the low pressure lockout on the Vokera Easi-Heat i 25C and 29C. The fault table in section 3 of Vokera's Easi-Heat i users and installation instructions (document 20195442, edition 3) gives the description as "Fill the system" and marks the code as definitive. Definitive means the boiler stays locked out until someone puts the pressure right and resets it. It will not clear itself the way a temporary warning does.

The boiler measures the heating circuit with a water pressure transducer. The manual explains that this transducer switches off the pump, fan and burner if the pressure drops below the rated tolerance, which protects the heat exchanger and pump from running short of water. So with A40 showing you will have no heating and, as the Easi-Heat i is a combi, no hot water either.

How A41 turns into A40

A40 does not appear the moment pressure dips. The manual describes a two stage warning:

  1. If the pressure falls below the 0.3 bar safety value, the boiler shows A41, also described as "Fill the system", for a transitional period of 10 minutes.
  2. If the pressure is still too low after those 10 minutes, the code changes to A40 and the boiler locks out.

That gives you a short window. If you spot A41 and top up straight away, you can often avoid the lockout altogether. The fault table also lists a "FIL" signal for low pressure and a separate signal when the pressure goes above 3.0 bar, so the display may warn you before either code appears.

DisplayMeaning in the Easi-Heat i manualWhat to do
FILLow pressure, check systemTop up to 1 to 1.5 bar
A41Fill the system (transitional, 10 minutes)Top up now to stop it becoming A40
A40Fill the system (definitive)Top up, then hold reset for more than two seconds
A42Pressure transducer fault (definitive)Gas Safe registered engineer
Above 3.0 barHigh pressure, check systemDo not top up; see below

Older Vokera models use A04

If your boiler is a Compact A, Unica i or another older Vokera, low pressure shows as A04, described as "insufficient system water pressure". The fix is much the same, but those boilers reset with the mode selector knob, so our Vokera A04 page is the better guide for them.

How to top up an Easi-Heat i and clear A40

The Easi-Heat i manual notes that the filling loop is not supplied with the boiler, so your installer will have fitted one. These steps follow section 2.13 of the manual:

  1. Turn the heating off and let the boiler cool.
  2. Find the filling valve connections, usually beneath the boiler.
  3. Attach the filling loop to both connections if it has been removed.
  4. Open the filling valve slowly until you hear water entering the system.
  5. Watch the pressure. The display shows it in standby, and it is also item I018 in the Info menu. Close the valve when it reads 1 to 1.5 bar.
  6. Remove the filling loop, with a cloth ready for a few drips.
  7. Hold the reset key for more than two seconds. If the right conditions have been restored, the boiler starts again.

For the pressure figures across other Vokera models, see our Vokera boiler pressure guide.

Do not overfill. The manual gives a maximum working pressure of 2.5 bar, and the pressure rises as the water heats. Stopping at 1 to 1.5 bar cold leaves enough headroom.

Why the pressure dropped

The manual's own cause for A40 is simply low system pressure. The useful question is where the water went:

  • Bleeding radiators or draining down for plumbing work lets water out on purpose. One top-up afterwards is normal.
  • Slow weeps at radiator valves, towel rails or hidden joints add up over weeks.
  • The pressure relief valve lets water out through its discharge pipe if the pressure rises too far when hot, usually because the expansion vessel has lost its charge.
  • An internal leak shows as water under the boiler. Look, but do not open the casing.

The manual says that frequent pressure loss may mean a leak, and that you should ask your installer to inspect the system. If the pressure drops very often, it tells you to contact Vokera's Technical Assistance Centre.

Why A40 matters more in winter

The Easi-Heat i has built-in frost protection that runs the burner or pump when the boiler temperature falls below 5°C. The manual says this relies on a permanent electrical supply and on the boiler not being in a fault state, and that it protects the appliance only. A boiler left locked out on A40 through a cold spell is not protecting itself, so top up and reset promptly rather than leaving it until the weekend.

When to call a Gas Safe registered engineer

Book an engineer if A40 returns within weeks of a top-up, if you see water dripping outside or under the boiler, if the pressure climbs above 2.5 bar when hot, if the display reads a healthy pressure but A40 will not clear, or if A42 appears. The engineer will normally check the expansion vessel charge, the relief valve, the visible joints and the transducer reading. Tell them how often you have topped up and the readings you saw.

Never remove the casing to look for an internal leak or to touch the expansion vessel. Water inside the boiler sits close to live parts and the gas supply, so it is a job for a Gas Safe registered engineer only.

Typical repair costs in the UK

JobTypical UK cost
Topping up yourselfFree
Engineer call-out and diagnosisTypically £60 to £150
Expansion vessel rechargeTypically £80 to £150
Pressure relief valveTypically £100 to £200
Pressure sensor (transducer) replacementTypically £100 to £220
Internal leak or pipe joint repairTypically £100 to £300

For the other codes we cover, see the Vokera fault code hub.

Frequently asked questions

What is the difference between Vokera A41 and A40?

Both mean "fill the system". A41 is a temporary warning shown when pressure drops below 0.3 bar, and if it is still low after 10 minutes the boiler switches to A40 and locks out.

How do I reset a Vokera Easi-Heat i after A40?

Top the pressure up to 1 to 1.5 bar with the filling loop, remove the loop, then hold the reset key for more than two seconds.

Why does my Vokera keep showing A40?

Water is leaving the system, through a leak, the pressure relief valve or after bleeding radiators. Vokera's manual says frequent pressure loss may mean a leak, so ask an engineer to inspect it.

Is Vokera A40 the same as A04?

They cover the same problem on different boilers. A40 is the Easi-Heat i low pressure code, while older models such as the Compact A and Unica i show A04 for insufficient system water pressure.

Sources

The meaning of A40 on this page comes from these manufacturer documents:

Codes and their meanings can change between models and software versions, so the manual for your exact boiler always comes first. Documents with a link open on the manufacturer's own website.

How the prices on this page were put together: typical UK prices for the parts and labour involved, shown as ranges rather than quotes. In October 2026 we compared them with the published UK price guides from Checkatrade, MyBuilder, MyJobQuote and Fantastic Services. Prices vary by area, boiler model and engineer, so always ask for a written quote.

Other Vokera fault codes

Full list →

Fault code meanings can differ between boiler models and software versions. Always check the user manual for your exact model. This page is general information, not a substitute for an inspection by a Gas Safe registered engineer. Read our disclaimer.