Vokera A03 Fault Code: Fan Fault Explained

Quick answer

A03 on most Vokera boilers is a fan fault. The boiler is not getting the correct speed signal back from its fan, so it cannot be sure the flue gases are being cleared and it locks out. A single reset can clear a one-off glitch, but if A03 returns the fan, its wiring or the control board needs a Gas Safe registered engineer.

On this page
  1. What the A03 code means
  2. Common causes of A03
  3. Safe checks you can do yourself
  4. When to call a Gas Safe engineer
  5. Typical repair costs in the UK
  6. How to stop A03 coming back

What the A03 code means

Modern Vokera boilers are room sealed, which means they draw air in and push waste gases out through the flue using a fan. The fan has a small sensor called a tacho that sends a speed signal back to the control board. The board uses that signal to check the fan is running at the speed it asked for before and during ignition.

In Vokera user manuals for models such as the Vision and Vision S, A03 is listed as a fan tacho signal fault, and newer code lists describe it simply as a fan fault. If the signal is missing or wrong, the boiler locks out, because burning gas without proof that the fan is clearing the flue would not be safe. The manual's action is to reset and check the appliance operation, and to check the fan.

You may see A03 described online as an overheat or pressure code. On the Vokera manuals we checked, it is the fan fault and low pressure is A04. Older and specialist models can differ, so check the table in your own manual.

Common causes of A03

A worn or failed fan

The fan runs every time the boiler fires. Over the years its bearings can wear, and it may slow down or stop. A fan on its way out often becomes noisy first, with a whine, hum or rattle when the boiler starts.

Faulty tacho signal or wiring

Sometimes the fan spins normally but the speed signal does not reach the board. A loose plug, damaged wire or failed sensor inside the fan can cause this. Faults of this type often come and go.

Control board fault

The board powers the fan and reads its signal. If the fan and wiring test correctly, the board may be the problem.

Power supply problems

A dip in the mains supply or a power cut while the boiler is starting can interrupt the fan and trigger A03. This usually clears with a single reset.

Flue or air intake restriction

A blocked or damaged flue can make the fan struggle. This is uncommon, and checking it is strictly an engineer job. If you notice anything obviously wrong with the flue outside, such as damage or a bird nest, mention it when you book rather than trying to deal with it yourself.

CauseTypical signWho fixes it
Power dip or cutA03 once, clears after a resetYou, by resetting
Worn fan bearingsWhining or rattling on start-upGas Safe engineer
Tacho sensor or wiring faultA03 comes and goes, fan sounds normalGas Safe engineer
Control board faultFan and wiring test correctlyGas Safe engineer
Flue restrictionFault under load or in strong windGas Safe engineer

Safe checks you can do yourself

There is no homeowner fix for a fan fault, but these checks may clear a one-off lockout and will help the engineer.

  1. Check the power. Make sure the fused spur for the boiler is switched on and that nothing else in the house has lost power.
  2. Reset the boiler once using the method in your manual. On many models you hold the reset button for a few seconds, and on some you turn the selector dial to the reset position.
  3. Listen while the boiler starts. Note any whining, grinding or rattling from inside the casing.
  4. Give it several minutes to run through ignition before deciding whether the reset worked.
  5. Stop after two or three attempts. Repeated resets will not fix a failing fan.

Do not remove the boiler casing or try to reach the fan. It sits in the sealed combustion section, and any work there, including on the flue, must be done by a Gas Safe registered engineer.

When to call a Gas Safe engineer

If A03 comes back after two or three resets, or if the boiler has been noisy for a while, call a Gas Safe registered engineer. They will check the fan's supply and speed signal, the wiring between the fan and the board, and the flue. They may also run a combustion check once the fault is fixed.

When you book, give the exact code, the model name on the front of the boiler and a description of any noise. Many engineers carry common Vokera parts, so good information improves the chance of a one-visit fix. If your boiler is still under warranty, contact Vokera or your installer first.

Typical repair costs in the UK

If a reset clears the fault for good, there is nothing to pay. If a part is needed, these typical ranges include parts and labour.

JobTypical UK cost
Engineer call-out and diagnosisTypically £80 to £150
Repairing fan wiring or a connectorTypically £80 to £150
Fan replacement, fittedTypically £180 to £350
Replacement PCBTypically £300 to £550
Flue repair or adjustmentTypically £100 to £300

How to stop A03 coming back

Fans wear gradually, so a yearly service is the best defence. The engineer checks combustion readings and listens to the fan, and can often spot wear before it becomes a breakdown. Our boiler service cost guide explains what is included. Do not ignore a boiler that has started to whine or rattle when it fires up. If your boiler also struggles to light, read our page on the Vokera A01 ignition failure, and see the Vokera fault code hub for the other codes we cover.

Frequently asked questions

What does A03 mean on a Vokera boiler?

On most Vokera models A03 is a fan fault. The boiler is not receiving the correct speed signal from its fan, so it locks out for safety.

Is Vokera A03 a low pressure fault?

Not on the Vokera manuals we checked. Low pressure is A04, while A03 is the fan fault. Check your own manual if you have an older or less common model.

Can I fix Vokera A03 myself?

You can check the power and reset the boiler once or twice. If A03 returns, the fan, wiring or board needs a Gas Safe registered engineer.

How much does a new fan for a Vokera boiler cost?

A fan replacement is typically £180 to £350 including parts and labour, depending on the model and where you live.

Other Vokera fault codes

Full list →

Fault code meanings can differ between boiler models and software versions. Always check the user manual for your exact model. This page is general information, not a substitute for an inspection by a Gas Safe registered engineer. Read our disclaimer.