Baxi E117 Fault Code: Water Pressure Too High Explained

Quick answer

E117 on a Baxi boiler means the water pressure in the heating system is too high, so the boiler has stopped. The most common causes are overfilling when topping up, a filling loop that has been left open or is letting water through, or an expansion vessel that has lost its charge. Check the filling loop is fully closed and bring the pressure down by bleeding a radiator, but call a Gas Safe registered engineer if it keeps rising.

On this page
  1. What the E117 code means
  2. Common causes of E117
  3. Safe checks you can do yourself
  4. When to call a Gas Safe engineer
  5. Typical repair costs in the UK
  6. How to stop E117 coming back

What the E117 code means

On Baxi models that use it, including the Baxi 100 series and EcoBlue boilers, E117 is described as "primary system water pressure too high". The primary system is the sealed circuit of water that runs between the boiler and your radiators. A pressure sensor inside the boiler watches that circuit all the time. If the reading climbs above the safe working limit, the boiler shuts down and shows E117.

High pressure matters because the system has a pressure relief valve, usually set to open at 3 bar. If the pressure reaches that point, the valve dumps water outside through a copper pipe. The boiler stopping before that happens gives you a chance to find the cause.

E117 is the opposite of the low pressure codes. Newer Baxi boilers show E118 for low pressure, and older ranges use E119. Some Baxi manuals do not list E117 at all, so check the fault table for your exact model.

Common causes of E117

Overfilling after a top-up

The simplest cause is too much water going in. If the system was topped up to 2 bar or more while cold, the pressure can rise well past that when the water heats up and expands.

Filling loop left open or letting by

A filling loop valve that has not been closed fully lets mains water creep into the system. Valves can also wear and let water pass even when they look closed, which engineers call letting by.

Expansion vessel lost its charge

The expansion vessel absorbs the extra volume as water heats. If it loses its air charge, there is nowhere for the water to go, so pressure shoots up when the heating runs and falls back when it cools.

Faulty pressure sensor

If the gauge reads normal but E117 keeps showing, the sensor may be giving a false reading.

Internal leak on a combi

Less often, on a combi the plate heat exchanger can fail internally and let mains water leak into the heating side. The pressure then creeps up even with the filling loop closed.

CauseTypical signWho fixes it
Overfilled systemGauge above 1.5 bar when cold, just after topping upYou, by bleeding a radiator
Filling loop left openPressure rises steadily, valve handle not fully closedYou, by closing the valves
Filling loop letting byPressure creeps up with valves closedGas Safe engineer or plumber
Expansion vessel lost chargePressure swings high when hot, low when coldGas Safe engineer
Faulty sensor or internal leakE117 persists, gauge reading does not matchGas Safe engineer

Safe checks you can do yourself

  1. Switch the heating off and let the system cool, then read the gauge. Pressure is always higher when hot, so a cold reading is the one that counts.
  2. Check both filling loop valves are fully closed. If yours is a removable braided hose, your manual may advise disconnecting it after use.
  3. If the cold pressure is above 1.5 bar, bleed a radiator slowly with a radiator key and a cloth to catch the water, watching the gauge. Close the bleed valve once the reading is between 1 and 1.5 bar.
  4. Press reset as your manual describes, no more than two or three times.
  5. Check the copper relief pipe outside for drips, which show the valve has been opening.
  6. Note the cold pressure each day for a week. If it creeps up again, something is letting water in.

Our guide to boiler pressure that is too high covers bleeding a radiator to lower the pressure in more detail.

Do not open the pressure relief valve, remove the casing or try to recharge the expansion vessel yourself. These parts are inside the boiler or connected to it and must be checked by a Gas Safe registered engineer.

When to call a Gas Safe engineer

If you have lowered the pressure and it climbs back up within a few days, call an engineer. The same applies if the pressure swings between very high when hot and low when cold, if water is dripping from the relief pipe outside, or if the gauge reads normal but E117 will not clear. The engineer will usually check the expansion vessel charge, test the filling loop valves, check the relief valve and test the pressure sensor.

It helps to keep a short record before the visit. Note the cold reading each morning and the reading after the heating has been on for an hour. A system that jumps from 1.5 bar cold to nearly 3 bar hot points strongly to the expansion vessel. A system that creeps up day by day, even when cold, points to water getting in through the filling loop or, on a combi, through the plate heat exchanger. Giving the engineer those numbers can shorten the diagnosis considerably.

Typical repair costs in the UK

Typical ranges only. Your bill depends on your area, the model and whether parts are in stock.

JobTypical UK cost
Engineer call-out and diagnosisTypically £80 to £150
Expansion vessel rechargeTypically £80 to £150
Filling loop valve replacementTypically £80 to £150
Pressure relief valve replacementTypically £120 to £220
Pressure sensor replacementTypically £100 to £200
Plate heat exchanger replacement (combi)Typically £200 to £400

How to stop E117 coming back

When you top up, fill slowly and stop at 1 to 1.5 bar with the system cold. Close both filling loop valves firmly and check the gauge again an hour later. Checking the pressure once a month helps you spot a slow rise before the boiler locks out. A yearly service lets an engineer check the expansion vessel charge before it causes trouble. See our boiler service cost guide for what is included.

Frequently asked questions

What does E117 mean on a Baxi boiler?

On Baxi models that use it, E117 means the primary system water pressure is too high. The boiler stops until the pressure is brought back into the normal range.

How do I lower the pressure on my Baxi boiler?

With the heating off and cool, bleed a radiator slowly and watch the gauge. Stop when it reads between 1 and 1.5 bar, then make sure the filling loop is fully closed.

Why does my Baxi pressure keep going up?

A filling loop that is letting water through, an expansion vessel that has lost its charge or, less often, an internal leak on a combi are the usual causes. These need a Gas Safe registered engineer.

Is high boiler pressure dangerous?

The boiler and the pressure relief valve are designed to stop pressure reaching unsafe levels. It is not an emergency, but a system that keeps running high should be checked.

Other Baxi fault codes

Full list →

Fault code meanings can differ between boiler models and software versions. Always check the user manual for your exact model. This page is general information, not a substitute for an inspection by a Gas Safe registered engineer. Read our disclaimer.