Baxi E28 Fault Code: Flue Sensor Fault Explained

Quick answer

E28 on a Baxi boiler is a "Flue NTC Fault", meaning the sensor that watches the temperature of the flue gases is giving a reading the boiler cannot use. Baxi lists it as a faulty component, and the related Potterton Gold Combi wording adds a blocked flue, blocked condensate or wiring fault, so check the outside pipes and then call a Gas Safe registered engineer.

On this page
  1. What E28 means
  2. Baxi and Potterton boilers that use E28
  3. Possible causes and how they differ
  4. Checks you can safely make
  5. What the engineer will check
  6. Typical repair costs in the UK
  7. When to call a Gas Safe registered engineer

What E28 means

E28 means your Baxi has lost a trustworthy signal from its flue temperature sensor and has locked out. Most of the time the sensor or its wiring needs attention from a Gas Safe registered engineer, although a blocked flue or condensate drain can also be behind it on some models.

A condensing boiler sends its exhaust gases out through a flue. The flue NTC is a thermistor that tells the control board how hot those gases are, which lets the boiler protect the flue and the heat exchanger from overheating. When the sensor reads open, shorted or wildly out of range, the board cannot do that job and shuts the burner down.

The Megaflo System HE IE manual (UK Comp No 5129838) groups E28 with E20 and says both "indicate faulty components". The Duo-tec Combi HE A manual (UK Comp No 5122323) uses the same "Flue NTC Fault" description.

Baxi and Potterton boilers that use E28

BoilerDocumentWording
Baxi Duo-tec Combi HE A (24, 28, 33, 40)Installation and Servicing Instructions, p.52Flue NTC Fault
Baxi Duo-tec 2 Combi GAInstallation and Servicing Instructions 7206334-08, p.45Flue NTC Fault
Baxi Assure Combi 25, 30, 36 (and LPG)Assure Combi User Guide, Table 9Code 28, "Flue NTC fault"
Baxi Megaflo System HE IEInstallation and Servicing Instructions, section 18.2Flue NTC Fault, a faulty component
Potterton Gold Combi 24, 28, 33User Guide, p.8Flue NTC Fault, Air Pressure Switch Fault, Blocked Flue, Blocked Condensate or Wiring Fault

The Gold Combi is built on the same Baxi platform, and its longer description is a useful clue to what else an engineer will look at on a Baxi showing E28.

Possible causes and how they differ

A failed flue sensor

This is the cause every Baxi document names. If the sensor itself has failed, E28 tends to appear the moment the boiler tries to fire and comes back straight after a reset.

Wiring or connection fault

A loose plug or damaged lead between the sensor and the board gives the same symptom. It can be intermittent, showing up some days and not others.

Blocked flue or blocked condensate

The Gold Combi wording lists both. A condensing boiler drains acidic water through its condensate pipe, and if that pipe freezes or blocks, the water backs up. A flue terminal that is covered or damaged stops the gases leaving properly. These causes are more likely when the code appears in freezing weather or after building work near the flue.

Air pressure switch

Also named in the Gold Combi table. This is an internal part and an engineer will test it if the sensor checks out.

E28 is not the same as E130

Baxi tables also list E130, "Flue NTC Operated". The Duo-tec manual explains that E130 means overheating in the flue system: the sensor is working and has measured a temperature that is too high. E28 means the sensor reading itself cannot be trusted.

Checks you can safely make

  • Look at the flue from outside. From the ground or a window, check that the terminal is not covered by anything such as a bag, sheeting or plant growth. Do not touch, move or try to clear the flue. Our boiler flue guide explains what a healthy terminal looks like.
  • Check the condensate pipe. In freezing weather, follow the plastic pipe outside and thaw any frozen section with warm (not boiling) water or a hot water bottle. Our frozen condensate pipe guide covers the steps.
  • Check the power supply. Make sure the fused spur is on and the display is lit.
  • Try one reset. If you have cleared a frozen condensate pipe, reset the boiler as the user guide describes. Stop after 2 or 3 attempts.

If a carbon monoxide alarm sounds, or you notice fumes, sooty marks or a smell near the boiler, switch the boiler off, open windows, get everyone into fresh air and call the National Gas Emergency Service on 0800 111 999. Never seal up or cover a flue.

What the engineer will check

The Duo-tec Combi HE A fault-finding chart gives the flue sensor's cold resistance as about 20kΩ at 25°C, double the figure for the heating sensor. The engineer will measure the sensor against that reference, inspect its plug and the lead back to the board, and test the air pressure switch where fitted. They should also inspect the flue route and terminal and the condensate trap and pipe, since a blockage in either can bring the code back after a new sensor has been fitted.

Typical repair costs in the UK

JobTypical cost
Engineer call-out and diagnosisTypically £60 to £150
Flue temperature sensor (NTC thermistor) replacedTypically £100 to £200
Sensor wiring or connector repairTypically £100 to £180
Flue repair or adjustmentTypically £150 to £400
Condensate pipe reroute or insulationTypically £80 to £200

When to call a Gas Safe registered engineer

Book an engineer if E28 returns after one or two resets, if the flue looks damaged, or if the code keeps coming back in cold spells even after you thaw the condensate pipe. Tell them the full code, the model, whether it shows at first light-up or after the boiler has run for a while, and what the weather was doing. If your boiler also shows E20, mention it, because two sensor codes together point the engineer towards the wiring or board.

Frequently asked questions

Can a frozen condensate pipe cause Baxi E28?

It can on some models. Baxi Duo-tec and Megaflo tables list E28 as a faulty flue sensor, but the Potterton Gold Combi, built on the same platform, includes a blocked condensate in its E28 description.

What is the difference between Baxi E28 and E130?

E28 means the flue sensor reading cannot be trusted. E130, "Flue NTC Operated", means the sensor is working and has detected overheating in the flue system.

Is it safe to keep resetting a Baxi with E28?

No. Try a reset once or twice after checking the condensate pipe, then stop. A flue fault needs a Gas Safe registered engineer to inspect it.

Does a Baxi Assure Combi show E28 as 28?

Yes. The Assure Combi user guide lists code 28 as "Flue NTC fault", shown with a symbol instead of the letter E.

Sources

The meaning of E28 on this page comes from these manufacturer documents:

  • Baxi, Duo-tec Combi 24, 28, 33 and 40 HE A: installation and servicing instructions, document Comp No 5122323, Iss 12, 2012.
  • Baxi, Duo-tec 2 Combi 24, 28, 33 and 40 GA: installation and servicing instructions, document 7206334-08, 2013.
  • Baxi, Assure Combi 25, 30 and 36: user guide.
  • Baxi, Megaflo System 15 to 32 HE IE: installation and servicing instructions, document Comp No 5129838, Iss 9, 2012.
  • Potterton, Gold Combi 24, 28 and 33: user guide, document 2015.

Codes and their meanings can change between models and software versions, so the manual for your exact boiler always comes first. Documents with a link open on the manufacturer's own website.

How the prices on this page were put together: typical UK prices for the parts and labour involved, shown as ranges rather than quotes. In October 2026 we compared them with the published UK price guides from Checkatrade, MyBuilder, MyJobQuote and Fantastic Services. Prices vary by area, boiler model and engineer, so always ask for a written quote.

Other Baxi fault codes

Full list →

Fault code meanings can differ between boiler models and software versions. Always check the user manual for your exact model. This page is general information, not a substitute for an inspection by a Gas Safe registered engineer. Read our disclaimer.