Baxi E04 10 Error: Burner Failed to Ignite

Quick answer

E.04.10 on a Baxi 400, 600 or 800 Combi 2 or Assure 500 means the burner failed to ignite after 4 attempts, so the boiler has locked out. The Baxi 200 and 400 Combi manual describes the same code as 5 burner start-up failures. Check that gas is reaching your home and the boiler, press reset no more than 2 or 3 times, and call a Gas Safe registered engineer if it returns.

On this page
  1. What E04 and E.04.10 mean
  2. Which Baxi boilers show E.04.10
  3. Other E04 codes you might see
  4. Why the burner fails to light
  5. Safe checks before you reset
  6. What the engineer will test
  7. Typical repair costs in the UK

What E04 and E.04.10 mean

E.04.10 is an ignition lockout. Your Baxi tried to light the burner several times, never detected a flame and shut itself down. Sometimes the cause is outside the boiler, such as a gas supply problem, but if gas is reaching the boiler it is an internal fault for a Gas Safe registered engineer.

Baxi's newer boilers use a three-part code. The letter E marks an error, the 04 is the fault group and the number after the second dot identifies the exact fault. The Combi 2/2.1 installation and service manual (7875578-02) lists the E.04 family as permanent faults, and the 600 Combi 2 manual heads the same table "permanent faults that require resetting". Unlike a temporary fault, the boiler will not try again by itself. It stays locked out until someone presses reset.

If you have a room unit or controller connected, it may show 254 rather than the boiler's code. Both the 400 Combi 2.1 and 600 Combi 2 manuals say to read the code on the boiler's own display.

Which Baxi boilers show E.04.10

BoilerDocumentWording for E.04.10
400 Combi 2.1, 600 Combi 2, 800 Combi 2, Assure 500 Combi 2Installation and Service Manual, Combi 2/2.1 (7875578-02), p.53"Burner failed to ignite after 4 attempts"
600 Combi 2 24, 30 and 36Installation and Service Manual, section 11, pp.76 to 77"Burner failed to ignite after 4 attempts"
200 Combi (224, 228) and 400 Combi (424, 428, LPG)Installation and Service Manual 7696317, pp.65 to 69"5 burner start-up failures" (shown as E:04.10)

Older Baxi boilers report a comparable situation as E133, "interruption of gas supply or flame failure", so our Baxi E133 page is the one to read if your boiler uses the older E codes.

Other E04 codes you might see

E04 on its own does not tell you much. The two digits after it matter, and the manuals list several:

CodeBaxi description
E.04.01Flow temperature sensor short circuited
E.04.02Flow temperature sensor disconnected
E.04.08Maximum safe temperature value reached
E.04.10Burner failed to ignite after 4 attempts
E.04.12Ignition failure, flame monitoring (false flame signal on the 200/400 Combi)
E.04.13Fan impeller blocked or maximum rpm exceeded
E.04.15Flue gas exhaust pipe blocked (600 Combi 2)
E.04.17Fault in gas valve control circuit

Why the burner fails to light

The manuals give engineers a list of things to check for the ignition faults. They fall into a few groups:

  • Gas supply. Gas supply pressure, and whether the gas valve is fully open. The 200/400 Combi manual also says to purge the gas supply to remove air, which is relevant after a new meter or work on the gas pipes.
  • Gas valve. Its electrical connection, calibration and operation.
  • Ignition. The electrode's condition and connections, and on the 200/400 Combi the cabling of the ignition transformer.
  • Other checks. Fan operation, flue blockages, the earth circuit and the supply voltage are also listed alongside the ignition codes.

Safe checks before you reset

  1. Test another gas appliance. If the hob will not light either, the problem is the supply, not the boiler.
  2. Check the meter. Make sure a prepayment meter has credit and the emergency control lever at the meter is on.
  3. Check the isolation valve. The gas valve on the pipe under the boiler should have its handle in line with the pipe. If it is across the pipe, it is closed.
  4. Think about recent work. If a meter was changed or gas pipework altered, tell the engineer, as air in the pipe needs purging by a professional.
  5. Reset. The 200/400 Combi manual says to press the RESET button for 5 seconds. On a Combi 2 or Assure 500, follow the reset method in your user guide. Allow no more than 2 or 3 attempts in total, because each one makes another round of ignition attempts.

Our guide to a boiler that will not fire up covers the same checks for other makes.

If you smell gas, do not press reset. Turn the supply off at the meter if you can do so safely, open doors and windows, avoid light switches and naked flames, and call the National Gas Emergency Service on 0800 111 999. The same number is the one to call if gas is not reaching any of your appliances.

What the engineer will test

A Gas Safe registered engineer will measure the gas pressure at the boiler, inspect the electrode for wear and position, check the ignition cabling and confirm the gas valve opens and is set correctly. If those pass, they will look at the fan, the flue route, the earth circuit and the supply voltage, following the order in Baxi's troubleshooting section.

The exact sub-code also steers the diagnosis. E.04.10 means the boiler never confirmed a flame, which points first at gas, the gas valve and the spark. E.04.12 relates to flame monitoring, which the 200/400 Combi manual words as a false flame signal, so the electrode and its wiring come under closer scrutiny there. E.04.13 and E.04.17 send the engineer straight to the fan or the gas valve circuit. That is why the full code matters more than the E04 at the front.

Typical repair costs in the UK

JobTypical cost
Engineer call-out and diagnosisTypically £60 to £150
Ignition electrode replacedTypically £90 to £180
Ignition lead or spark generatorTypically £100 to £200
Gas valve replacementTypically £180 to £350
Flue repair or adjustmentTypically £150 to £400

When you book, give the full code (E.04.10, not just E04), the model and whether other gas appliances work. Mention any recent meter change, gas work or power cut, and how many resets you have tried. If the boiler is under its Baxi warranty, contact Baxi first. Our Baxi fault code hub lists the other Baxi codes we cover.

Frequently asked questions

How do I reset E.04.10 on a Baxi Combi 2 boiler?

Check your gas supply first, then press the reset button as your user guide describes (the 200 and 400 Combi manual says hold RESET for 5 seconds). Stop after 2 or 3 attempts and call a Gas Safe registered engineer if it returns.

Why does my Baxi show E04 10 after a new gas meter was fitted?

Baxi lists purging air from the gas supply among its ignition checks, and air can enter the pipe when a meter is changed. Ask a Gas Safe registered engineer to purge the supply and check the pressure.

Is Baxi E.04.10 the same as E133 on older Baxi boilers?

They cover a similar situation. E133 on older Baxi boilers means an interruption of gas supply or flame failure, while E.04.10 on Combi 2 boilers specifically means the burner failed to ignite after repeated attempts.

What does E.04.13 mean on a Baxi Combi 2?

Baxi describes E.04.13 as the fan impeller being blocked or the fan exceeding its maximum speed. It is an internal fault for a Gas Safe registered engineer.

Why does my Baxi room controller show 254 instead of E04?

Baxi manuals say a connected room unit can show 254 during a fault. Read the code on the boiler display itself to find the actual E.04 number.

Sources

The meaning of E.04.10 on this page comes from these manufacturer documents:

  • Baxi, 400 Combi 2.1, 600 Combi 2, 800 Combi 2 and Assure 500 Combi 2: installation and service manual, document 7875578-02.
  • Baxi, 600 Combi 2 24, 30 and 36: installation and service manual.
  • Baxi, 200 Combi (224 and 228) and 400 Combi (424 and 428): installation and service manual, document 7696317-1, 2018.

Codes and their meanings can change between models and software versions, so the manual for your exact boiler always comes first. Documents with a link open on the manufacturer's own website.

How the prices on this page were put together: typical UK prices for the parts and labour involved, shown as ranges rather than quotes. In October 2026 we compared them with the published UK price guides from Checkatrade, MyBuilder, MyJobQuote and Fantastic Services. Prices vary by area, boiler model and engineer, so always ask for a written quote.

Other Baxi fault codes

Full list →

Fault code meanings can differ between boiler models and software versions. Always check the user manual for your exact model. This page is general information, not a substitute for an inspection by a Gas Safe registered engineer. Read our disclaimer.