Baxi E118 Fault Code: Primary Water Pressure Too Low

Quick answer

E118 on a Baxi boiler means the primary system water pressure is too low, so the boiler will not run. On most newer Baxi boilers it appears when pressure drops below about 0.5 bar. You can usually clear it by topping the system up to 1 to 1.5 bar through the filling loop, but if the pressure keeps falling there is a leak or a faulty part to find.

On this page
  1. What the E118 code means
  2. Common causes of E118
  3. Safe checks you can do yourself
  4. When to call a Gas Safe engineer
  5. Typical repair costs in the UK
  6. How to stop E118 coming back

What the E118 code means

E118 is the low pressure code on newer Baxi boilers, including the Baxi 100 and 600 series and many EcoBlue models. The manuals describe it as "primary system water pressure too low". Older Baxi ranges such as the Duo-tec and Platinum report low pressure as E119 instead, so the code you see depends on the age of your boiler rather than on a different fault.

The primary system is the sealed loop of water that the boiler heats and pumps round your radiators. A pressure sensor checks that there is enough water in it before the burner is allowed to fire. Baxi user guides give a normal working range of about 1 to 2 bar and say the boiler will stop below 0.5 bar. Stopping protects the pump and heat exchanger from running short of water.

On many newer Baxi displays the fault shows as the number 118 next to a symbol, rather than with a letter E in front. An R symbol means the code can be reset by the user once the cause is dealt with. A spanner symbol means it needs an engineer.

Common causes of E118

Gradual loss over months

Sealed systems slowly lose a little pressure over time. If nobody has checked the gauge for a year or more, a slow drift below the limit may be all that has happened.

Radiators bled recently

Letting air out of radiators also lets out some pressure. Bleeding several in one session often takes the system below the minimum.

Leaks

Weeping radiator valves, towel rails and pipe joints can lose enough water to trigger E118 within days or weeks. Look for damp carpets, stains on ceilings and green or white crust around fittings. Our guide to a boiler leaking water covers leaks at the boiler itself.

Relief valve and expansion vessel

If the expansion vessel has lost its charge, pressure rises too far when hot and the relief valve lets water out. Once the system cools, the pressure is lower than before. Repeated over weeks, this pattern ends in E118.

Faulty pressure sensor

If the gauge shows normal pressure but E118 remains, the sensor or its wiring may be at fault.

CauseTypical signWho fixes it
Slow pressure lossNo other symptoms, gauge lowYou, via the filling loop
Radiators recently bledPressure fell straight afterwardsYou, via the filling loop
Leak on pipes or radiatorsDamp patches, pressure keeps droppingPlumber or Gas Safe engineer
Expansion vessel or relief valveHigh when hot, drips from outside pipeGas Safe engineer
Faulty pressure sensorGauge normal, E118 will not clearGas Safe engineer

Safe checks you can do yourself

  1. Turn the heating off and let the system cool, then read the pressure gauge under or on the front of the boiler.
  2. Find the filling loop. Many Baxi boilers have one built in under the boiler, while others use a separate braided hose with a valve at each end. Your user guide shows which you have.
  3. Open the filling loop slowly and watch the gauge. Close it as soon as the reading reaches 1 to 1.5 bar.
  4. Check the valves are fully closed. A loop left slightly open will push the pressure too high and can cause E117 on models that use it.
  5. If the code does not clear by itself, press reset for about one second as the manual describes. Try no more than two or three times.
  6. Check radiators, visible pipes and the area under the boiler for signs of water.
  7. Write down the pressure and check it daily for a week.

New to topping up? Our step-by-step guide on how to repressurise a boiler walks through it with pictures of the common filling loop types.

Do not overfill. If the cold pressure is above 1.5 bar it can climb too high once the heating runs.

When to call a Gas Safe engineer

One top-up after bleeding radiators is routine. Book a Gas Safe registered engineer if you need to top up again within a few weeks, if water drips from the copper pipe outside, if you find water under the boiler, or if the gauge reads normal but E118 will not clear. The expansion vessel, relief valve and pressure sensor are all inside the boiler, so they must not be touched by a homeowner. A leak on a radiator or pipe away from the boiler can normally be fixed by a plumber.

When you book, tell the engineer how often you have been topping up and by how much. Losing half a bar over a month suggests a very slow weep, while losing a whole bar in a day suggests a larger leak or the relief valve opening.

Never remove the boiler casing to look for an internal leak. Water near live electrical parts and gas components is a job for a qualified engineer only.

Typical repair costs in the UK

These are typical ranges, not quotes, and vary by area and access.

JobTypical UK cost
Topping up pressure yourselfFree
Engineer call-out and diagnosisTypically £80 to £150
Radiator valve or joint leak repairTypically £80 to £200
Expansion vessel rechargeTypically £80 to £150
Pressure sensor replacementTypically £100 to £200
Pressure relief valve replacementTypically £120 to £220

How to stop E118 coming back

Check the gauge once a month and before winter starts. Top up after bleeding radiators rather than waiting for the boiler to lock out. Deal with small drips early, as a slow leak is the most common reason for repeated E118. An annual service lets an engineer check the expansion vessel and relief valve. Our boiler service cost guide explains what to expect.

Frequently asked questions

What is the difference between Baxi E118 and E119?

Both mean low water pressure. E118 is used on newer Baxi boilers such as the 100 and 600 series, while older ranges like the Duo-tec and Platinum show E119.

What pressure should my Baxi boiler be at?

Baxi user guides give a working range of about 1 to 2 bar. With the heating cold, aim for 1 to 1.5 bar so there is room for the pressure to rise when hot.

Can I fix E118 myself?

Usually, yes. Top up to 1 to 1.5 bar with the filling loop, close the valves and reset if needed. If the pressure keeps dropping, call a Gas Safe registered engineer.

Why does E118 show when the gauge looks fine?

If the gauge reads 1 to 1.5 bar but E118 will not clear after two or three resets, the pressure sensor or its wiring may be faulty. That needs an engineer.

How long can I leave E118 before fixing it?

The boiler will not provide heating or hot water until the pressure is restored, so top up as soon as you can. The fault itself is not dangerous.

Other Baxi fault codes

Full list →

Fault code meanings can differ between boiler models and software versions. Always check the user manual for your exact model. This page is general information, not a substitute for an inspection by a Gas Safe registered engineer. Read our disclaimer.