E50 Fault Code on a Baxi: Hot Water Sensor Fault

Quick answer

E50 on a Baxi combi is a "Hot Water NTC Fault": the sensor that measures the temperature of your tap hot water has failed or is giving a false reading. It appears on the Duo-tec Combi HE A and matching Potterton combis, while newer Baxi ranges report the same fault as code 321. It needs a Gas Safe registered engineer to replace the sensor or repair its wiring.

On this page
  1. What E50 means
  2. Which boilers show E50, and which show 321
  3. Likely causes
  4. What you can check before calling someone
  5. What the engineer will do
  6. Typical repair costs in the UK
  7. Related Baxi sensor faults

What E50 means

E50 is a sensor fault on the hot water side of a Baxi combi. The boiler's board is no longer getting a sensible reading from the hot water temperature sensor, so it cannot control how hot the water to your taps is. The fix is normally a replacement sensor or a repaired connection, carried out by a Gas Safe registered engineer.

The sensor is an NTC thermistor, whose resistance drops as the water passing it warms up. A combi heats tap water on demand, and the board uses this reading to adjust the burner so the water arrives at the temperature you have set. Without it, the board has no way of knowing whether the water is lukewarm or scalding.

Baxi's Duo-tec Combi HE A installation and servicing instructions (UK Comp No 5122323) list E50 as "Hot Water NTC Fault" and add that it is shown on the display as E and then 50.

Which boilers show E50, and which show 321

This is the part that confuses people searching for the code. Baxi changed the numbering on its newer ranges, so the same fault has two codes depending on the age of your boiler.

BoilerDocumentCode for a hot water sensor fault
Baxi Duo-tec Combi 24, 28, 33, 40 HE AInstallation and Servicing Instructions, p.52E50 (shown as E, then 50)
Potterton Promax Combi HE Plus AUser Guide, UK Comp No 5114443, section 5.3E50
Potterton Gold Combi 24, 28, 33User Guide, p.8E50
Baxi Duo-tec 2 Combi GAInstallation and Servicing Instructions 7206334-08321
Baxi Assure Combi 25, 30, 36Assure Combi User Guide, Table 9321, "Hot water NTC fault"
Potterton Promax UltraPromax Ultra fault table321

E50 does not appear in the Duo-tec 2, Assure or Promax Ultra tables. If your boiler shows 321, everything on this page still applies. We did not find E50 in the Megaflo System HE IE table either, which fits with a system boiler heating a separate hot water cylinder rather than tap water directly.

Because these older displays only have two characters, it helps to be sure what you are reading. "E" followed by "50" is E50. "E1" followed by two digits is a three-digit code, which our Baxi E1 guide explains how to read.

Likely causes

Every source we checked names the same cause: a faulty hot water sensor. In practice an engineer will treat it as one of three things:

  • the thermistor itself has failed, which is the most common outcome for an NTC code;
  • the plug on the sensor has worked loose or corroded;
  • the lead from the sensor back to the control board is damaged.

All three are inside the casing on the hot water side of the boiler, so this is not a code you can fix by topping up pressure or bleeding radiators.

What you can check before calling someone

  1. Confirm the code. Watch the display change and make sure you have E then 50, or 321 on a newer model.
  2. Test the heating side. Turn the heating up at the thermostat and note whether the radiators warm. Whatever you find is useful information for the engineer, and our guide to no hot water when the heating works covers other causes of that pattern.
  3. Check more than one hot tap. Note whether every hot tap is affected, and whether the code appears as soon as you open a tap.
  4. Check the power. Make sure the boiler's fused spur is on and the display is lit.
  5. Try one reset. Turn the selector to Reset and hold it for 5 seconds on a Duo-tec, Promax or Gold. If E50 comes straight back, the sensor circuit is still faulty.

Do not take the cover off to reach the sensor. It sits next to hot pipework, gas components and live wiring, and work inside a gas boiler is for a Gas Safe registered engineer only.

What the engineer will do

The engineer will isolate the boiler, open it and test the hot water sensor's resistance, checking that it changes as expected with temperature. The Duo-tec fault-finding chart gives cold resistance figures for the heating and flue sensors but not for the hot water sensor, so the engineer will work from Baxi's data for that part. They will also check the plug and the lead to the board. Once a new sensor is fitted, they should run a hot tap and confirm that the outlet temperature settles at the setting on the boiler.

Typical repair costs in the UK

JobTypical cost
Engineer call-out and diagnosisTypically £60 to £150
Hot water temperature sensor (NTC thermistor) replacedTypically £100 to £200
Sensor connector or wiring repairTypically £100 to £180

If your Baxi or Potterton is still under warranty, contact Baxi first so the repair does not affect a claim.

What to tell the engineer when you book

A few details help the engineer arrive with the right part and avoid a second visit:

  • the exact code, E50 or 321, and the model name from the front of the boiler;
  • whether the radiators still heat up when the code is showing;
  • whether the code appears every time a hot tap is opened or only now and then;
  • how many times you have reset the boiler and whether the code came straight back.

E50 belongs to the same group as E20 for the central heating sensor and E28 for the flue sensor. If more than one of them appears, tell the engineer, because a shared connection or board fault becomes more likely than several sensors failing together. Our Baxi fault code hub lists every Baxi code we cover.

Frequently asked questions

My Baxi shows 321, not E50. Is it the same fault?

Yes. Newer Baxi ranges such as the Duo-tec 2 GA and Assure Combi list 321 as "Hot water NTC fault", which older Duo-tec HE A boilers report as E50.

Can I reset Baxi E50 myself?

You can try one reset using the selector switch, held at Reset for 5 seconds. If E50 returns, the sensor or its wiring needs a Gas Safe registered engineer.

How much does it cost to fix Baxi E50?

A hot water sensor replacement typically costs £100 to £200 in the UK, and a call-out with diagnosis typically costs £60 to £150.

Do Baxi system boilers show E50?

We did not find E50 in the Megaflo System HE IE fault table. The documents we checked list it on combis such as the Duo-tec Combi HE A and Potterton Gold Combi.

Sources

The meaning of E50 on this page comes from these manufacturer documents:

  • Baxi, Duo-tec Combi 24, 28, 33 and 40 HE A: installation and servicing instructions, document Comp No 5122323, Iss 12, 2012.
  • Potterton, Promax Combi HE Plus A: user guide, document Comp No 5114443, Iss 16, 2012 (and the 2008 edition).
  • Potterton, Gold Combi 24, 28 and 33: user guide, document 2015.

Codes and their meanings can change between models and software versions, so the manual for your exact boiler always comes first. Documents with a link open on the manufacturer's own website.

How the prices on this page were put together: typical UK prices for the parts and labour involved, shown as ranges rather than quotes. In October 2026 we compared them with the published UK price guides from Checkatrade, MyBuilder, MyJobQuote and Fantastic Services. Prices vary by area, boiler model and engineer, so always ask for a written quote.

Other Baxi fault codes

Full list →

Fault code meanings can differ between boiler models and software versions. Always check the user manual for your exact model. This page is general information, not a substitute for an inspection by a Gas Safe registered engineer. Read our disclaimer.